Determination of Nd3+ Ions in Solution Samples by a Coated Wire Ion-Selective Sensor

被引:27
|
作者
Zamani, Hassan Ali [1 ]
机构
[1] Islamic Azad Univ, Quchan Branch, Dept Appl Chem, Quchan, Iran
关键词
Coated wire electrode; Ion-selective electrode; PVC membrane; Sensor; Potentiometry; PVC-MEMBRANE-ELECTRODE; SEDIMENT SAMPLES; WASTE-WATER; ERBIUM-ION; CONSTRUCTION; SOIL; FABRICATION; BASE; CARRIER;
D O I
10.1155/2012/360769
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new coated wire electrode (CWE) using 5-(methylsulfanyl)-3-phenyl-1H-1,2,4-triazole (MPT) as an ionophore has been developed as a neodymium ion-selective sensor. The sensor exhibits Nernstian response for the Nd3+ ions in the concentration range of 1.0x10(-6)-1.0x10(-2) M with detection limit of 3.7x10(-7) M. It displays a Nernstian slope of 20.2 +/- 0.2 mV/decade in the pH range of 2.7-8.1. The proposed sensor also exhibits a fast response time of similar to 5 s. The sensor revealed high selectivity with respect to all common alkali, alkaline earth, transition and heavy metal ions, including members of the lanthanide family other than Nd3+. The electrode was used as an indicator electrode in the potentiometric titration of Nd(III) ions with EDTA. The electrode was also employed for the determination of the Nd3+ ions concentration in water solution samples.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 50 条
  • [21] Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes
    Schnierle, P
    Kappes, T
    Hauser, PC
    ANALYTICAL CHEMISTRY, 1998, 70 (17) : 3585 - 3589
  • [22] NOVEL COATED WIRE ION-SELECTIVE ELECTRODES FOR ESTIMATION OF PERRHENATE ION
    AGARWALA, V
    CHATTOPADHYAYA, MC
    ANALUSIS, 1993, 21 (08) : 349 - 352
  • [23] Ion-Selective Electrode for the Determination of Dimethylbenzylammonium Ions
    Kopytin, A. V.
    Urusov, Yu. I.
    Zhukov, A. F.
    Kokunov, Yu. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (01) : 73 - 77
  • [24] Ion-selective electrode for the determination of dimethylbenzylammonium ions
    A. V. Kopytin
    Yu. I. Urusov
    A. F. Zhukov
    Yu. V. Kokunov
    Journal of Analytical Chemistry, 2011, 66 : 73 - 77
  • [25] PLASTIC MEMBRANE AND COATED WIRE ION-SELECTIVE ELECTRODES FOR PROPYLHEXEDRINE
    ZAREH, M
    ELSHEIKH, R
    ISSA, YM
    SHOUKRY, AF
    ANALYTICAL LETTERS, 1992, 25 (04) : 663 - 680
  • [26] STUDY ON COATED WIRE CALCIUM ION-SELECTIVE ELECTRODE.
    Li, Xichun
    Zeng, Binli
    Xu, Xilin
    Ning, Aipin
    Zhongnan Kuangye Xueyuan Xuebao/Journal of Central-South Institute of Mining and Metallurgy, 1987, 18 (01): : 93 - 97
  • [27] KINETIC POTENTIOMETRIC DETERMINATION OF IODIDE WITH AN ANTIMONY(V) COATED-WIRE ION-SELECTIVE ELECTRODE
    SANCHEZPEDRENO, C
    ORTUNO, JA
    ROS, AL
    ANALYST, 1992, 117 (10) : 1619 - 1621
  • [28] DETERMINATION OF THE CRITICAL MICELLE CONCENTRATION OF NEUTRAL SURFACTANTS BY MEANS OF A COATED WIRE ION-SELECTIVE ELECTRODE
    FERRARA, D
    YU, WH
    FREISER, H
    COLLOIDS AND SURFACES, 1991, 59 : 113 - 118
  • [29] A novel coated wire magnesium(II) ion-selective electrode: Determination of magnesium in dolomite sample
    Kumari, PJ
    Chattopadhyaya, MC
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2000, 77 (07) : 358 - 359
  • [30] Ion-selective electrode for lanthanum determination in standard samples
    Khalil, S
    ANALYTICAL LETTERS, 2003, 36 (07) : 1335 - 1349