Titanium alloy pins versus stainless steel pins in external fixation at the wrist: A randomized prospective study

被引:32
|
作者
Pieske, Oliver [1 ]
Geleng, Patrizia [1 ]
Zaspel, Johannes [1 ]
Piltz, Stefan [1 ]
机构
[1] Univ Munich, Dept Surg, D-81377 Munich, Germany
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2008年 / 64卷 / 05期
关键词
distal radius fracture; ttitanium alloy; stainless steel; external fixation; complications;
D O I
10.1097/TA.0b013e31815e40e0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. Pin-track complications remain the most troublesome disadvantages of external fixation. The purpose of this study was to compare pin-related complications and pain levels after the use of external fixation for the stabilization of distal radial fractures with pins composed of two different materials. Methods: In a prospective trail 80 patients (320 pins) with unstable distal radial fracture were randomized for standard small AO-external fixator treatment with the use of identical pin geometry either composed of stainless-steel (Ss) (n = 40) or titanium alloy (Ti6Al4V) (n = 40). The patients were followed at biweekly intervals until the external fixators were removed (44 days after surgery). The patients were evaluated with regard to erythema, drainage, cellulitis, occurrence of pain at each pinsite, clinical or radiographic evidence of pin-loosening, the need for antibiotics, and the need for pin removal before fracture-healing due to infection. Results:. The complication rate was 21%, and age was found to be significantly associated with an increased risk of pin-loosening (p = 0.003). There were no significant differences among the two groups with regard to the prevalence of pin-site complications. However, the rate of premature removal of fixator because of severe pin-track infection (5% vs. 0%) and the rate of pin-loosening (10% vs. 5%) was higher in the Ss-pin group. Furthermore, pain values were significantly reduced in the Ti6Al4V-pin group. Conclusions:. The use of Ti6Al4V-pin external fixator in distal radial fractures yields a trend of reduced pin-related complications and significantly reduced pain levels than does the Ss-pin fixator.
引用
收藏
页码:1275 / 1280
页数:6
相关论文
共 50 条
  • [21] Prospective, surgeon-randomized evaluation of crossed pins versus lateral pins for unstable supracondylar humerus fractures in children
    Tripuraneni, Krishna R.
    Bosch, Patrick P.
    Schwend, Richard M.
    Yaste, Jeffrey J.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2009, 18 (02): : 93 - 98
  • [22] Titanium miniplates or stainless steel wire for cranial fixation: a prospective randomized comparison
    Broaddus, WC
    Holloway, KL
    Winters, CJ
    Bullock, MR
    Graham, RS
    Mathern, BE
    Ward, JD
    Young, HF
    JOURNAL OF NEUROSURGERY, 2002, 96 (02) : 244 - 247
  • [23] Improvement of the bone-pin interface strength in osteoporotic bone with use of hydroxypatite-coated tapered external-fixation pins - A prospective, randomized clinical study of wrist fractures
    Moroni, A
    Faldini, C
    Marchetti, S
    Manca, M
    Consoli, V
    Giannini, S
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (05): : 717 - 721
  • [24] A biomechanical and histological analysis of standard versus hydroxyapatite-coated pins for external fixation
    Moroni, Antonio
    Cadossi, Matteo
    Romagnoli, Matteo
    Faldini, Cesare
    Giannini, Sandro
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (02) : 417 - 421
  • [25] Circular External Fixation Frames with Divergent Half Pins A Pilot Biomechanical Study
    Lenarz, Christopher
    Bledsoed, Gary
    Watson, J. Tracy
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (12) : 2933 - 2939
  • [26] Placement of half-pins for supra-acetabular external fixation: An anatomic study
    Haidukewych, GJ
    Kumar, S
    Prpa, B
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (411) : 269 - 273
  • [27] No clinical benefits using a new design of pins for external fixation: a randomized study in 50 patients operated on by the hemicallotasis technique
    W-Dahl, Annette
    Toksvig-Larsen, Soeren
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (07) : 661 - 667
  • [28] No clinical benefits using a new design of pins for external fixation: a randomized study in 50 patients operated on by the hemicallotasis technique
    Annette W-Dahl
    Sören Toksvig-Larsen
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 661 - 667
  • [29] External Fixation and Adjuvant Pins Versus Volar Locking Plate Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study With a 5-Year Follow-Up
    Williksen, John H.
    Husby, Torstein
    Hellund, Johan C.
    Kvernmo, Hebe D.
    Rosales, Carina
    Frihagen, Frede
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (07): : 1333 - 1340
  • [30] A comparison of hydroxyapatite-coated, titanium-coated, and uncoated tapered external-fixation pins -: An in vivo study in sheep
    Moroni, A
    Toksvig-Larsen, S
    Maltarello, MC
    Orienti, L
    Stea, S
    Giannini, S
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04): : 547 - 554