A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment

被引:41
作者
Bogaert, E. [1 ]
Bacher, K. [1 ]
Thierens, H. [1 ]
机构
[1] Univ Ghent, Dept Med Phys & Radiat Protect, B-9000 Ghent, Belgium
关键词
D O I
10.1093/rpd/ncm379
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, a large-scale multicentre patient dose study performed in eight Belgian interventional cardiology departments is presented. Effective dose (E) was calculated based on a detailed dose-area product (DAP)-registration during each procedure and by using conversion coefficients generated by the Monte Carlo-based computer program PCXMC. Conversion coefficients were found to be 0.177 mSv Gycm(-2) for systems that do not use any additional copper filtration in cineradiography and 0.207 mSv Gycm(-2) for systems that use additional copper filtration in cineradiography. Mean E values of 9.6 and 15.3 mSv for diagnostic and therapeutic procedures, respectively, were obtained. DAP distributions were investigated in order to derive dose reference levels: 71 and 106 Gycm(2) for diagnostic and therapeutic procedures, respectively, are proposed. Significant differences were observed in DAP distributions taking into account whether additional copper filtration was used in the cineradiography mode. Apart from the skin, the organs most at risk are lungs and heart. The probability of fatal cancer for the studied population amounted to 1.1 x 10(-4) and 2.1 x 10(-4) for diagnostic and therapeutic procedures, respectively, for the age distribution of the patients considered in this multicentre study.
引用
收藏
页码:312 / 323
页数:12
相关论文
共 24 条
[1]  
[Anonymous], 1991, 1990 recommendations of the international commission on radiological protection ICRP publication 60
[2]  
[Anonymous], 1980, NUREGCR1159
[3]   Adult reference levels in diagnostic and interventional radiology for temporary use in Switzerland [J].
Aroua, A ;
Besançon, A ;
Buchillier-Decka, I ;
Trueb, P ;
Valley, JF ;
Verdun, FR ;
Zeller, W .
RADIATION PROTECTION DOSIMETRY, 2004, 111 (03) :289-295
[4]   Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization [J].
Bacher, K ;
Bogaert, E ;
Lapere, R ;
De Wolf, D ;
Thierens, H .
CIRCULATION, 2005, 111 (01) :83-89
[5]   Patient radiation doses during cardiac catheterization procedures [J].
Betsou, S ;
Efstathopoulos, EP ;
Katritsis, D ;
Faulkner, K ;
Panayiotakis, G .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (846) :634-639
[6]  
BOGAERT E, 2005, MULTICENTRE STUDY SK
[7]   A PHANTOM BASED METHOD FOR DERIVING TYPICAL PATIENT DOSES FROM MEASUREMENTS OF DOSE-AREA PRODUCT ON POPULATIONS OF PATIENTS [J].
CHAPPLE, CL ;
BROADHEAD, DA ;
FAULKNER, K .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (814) :1083-1086
[8]  
Delichas MG, 2003, RADIAT PROT DOSIM, V103, P149, DOI 10.1093/oxfordjournals.rpd.a006126
[9]  
*EUR COMM, 1997, 91 EUR COMM
[10]   RADIATION-DOSES AND SOMATIC RISK TO PATIENTS DURING CARDIAC RADIOLOGICAL PROCEDURES [J].
FAULKNER, K ;
LOVE, HG ;
SWEENEY, JK ;
BARDSLEY, RA .
BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (700) :359-363