Simultaneous Analysis of 10 Priority PAHs in Iranian Sangak Bread Samples by Developing a GC-MS Method

被引:5
|
作者
Peiravian, Farzad [1 ]
Shakoori, Attaollah [2 ]
Moradi, Vahideh [2 ]
Salamzadeh, Jamshid [3 ]
Mahboubi, Arash [4 ]
机构
[1] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmacoecon & Pharma Management, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Food & Drugs Affairs, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Food Safety Res Ctr, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmaceut, Tehran, Iran
来源
IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH | 2021年 / 20卷 / 02期
关键词
GC-MS; Poly Aromatic Hydrocarbons (PAHs); Sangak bread; Iran; POLYCYCLIC AROMATIC-HYDROCARBONS; PESTICIDE-RESIDUES; MASS-SPECTROMETRY; DIETARY EXPOSURE; EXTRACTION; FOOD; INJECTION;
D O I
10.22037/ijpr.2020.113074.14097
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Human exposure to polycyclic aromatic hydrocarbons (PAHs) is known as a carcinogen risk factor. In this study, a gas chromatography-mass spectrometry (GC-MS) technique combined with the QuEChERS extraction method was developed for concurrent analysis of 10 polycyclic aromatic hydrocarbons (PAHs) in Iranian traditional Sangak bread samples. The method was validated by determining different parameters, including; linearity, accuracy, precision, limit of detection (LOD) and limit of quantitation (LOQ). Calibration curves showed a linear relationship in the concentration range of 10-500 ng/g with a coefficient of determination (R-2) ranged between 0.994 and 0.999. The obtained mean recoveries were 92-106% with the relative standard deviations (RSDs) in the range of 3-7% with an acceptable precision (RSD < 20%). The Limit of detections (LODs) for different PAHs were between 0.14-0.78 ng/g, while the limit of quantitation (LOQ) was 0.46-2.60 ng/g. Matrix effect studies showed that the analytes concluded signal suppressions or enhancements. Therefore, spiked calibration curves were used for overcoming this issue. The result of Sangak bread samples analysis using the validated method showed that 9 (19.4%) out of 47 Sangak bread samples were contaminated with phenanthrene (PHE) and anthracene (ANT) at the mean level of 10.08 +/- 6.38 ng/g which were higher than the permissible limit of European Commission regulatory control value for BaP (1 mu g/kg of wet weight) in processed cereal-based foods and baby foods for infants and young children.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [41] Identification and Analysis of the Impurities for Triethylboron by GC-MS Method
    Su, Pengfei
    Xiu-tian-feng, E.
    Wang, Jingna
    Zhu, Yanlong
    Zhang, Gao
    Chang, Hai
    Liu, Ke
    Meng, Zihui
    PROPELLANTS EXPLOSIVES PYROTECHNICS, 2022, 47 (04)
  • [42] Optimized conditions for simultaneous determination of opiates, cocaine and benzoylecgonine in hair samples by GC-MS
    Romolo, FS
    Rotolo, MC
    Palmi, I
    Pacifici, R
    Lopez, A
    FORENSIC SCIENCE INTERNATIONAL, 2003, 138 (1-3) : 17 - 26
  • [43] The application of d-SPE in the QuEChERS method for the determination of PAHs in food of animal origin with GC-MS detection
    Surma, Magdalena
    Sadowska-Rociek, Anna
    Cieslik, Ewa
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2014, 238 (06) : 1029 - 1036
  • [44] Analysis of polychlorinated biphenyls (PCBs) in edible oils using the QuEChERS/GC-MS method: A health risk assessment study
    Eghbaljoo, Hadi
    Ghalhari, Mohammad Rezvani
    Shariatifar, Nabi
    Khaniki, Gholamreza Jahed
    Aghaee, Ebrahim Molaee
    Sani, Mahmood Alizadeh
    Mansouri, Elahe
    Arabameri, Majid
    HELIYON, 2023, 9 (11)
  • [45] Comparison of GC-MS and HPLC for overcoming matrix interferences in the analysis of PAHs in smoked food
    Chiu, CP
    Lin, YS
    Chen, BH
    CHROMATOGRAPHIA, 1997, 44 (9-10) : 497 - 504
  • [46] Comparison of GC-MS and HPLC for overcoming matrix interferences in the analysis of PAHs in smoked food
    C. P. Chiu
    Y. S. Lin
    B. H. Chen
    Chromatographia, 1997, 44 : 497 - 504
  • [47] Sorbent-excluding sample preparation method for GC-MS pesticide analysis in apple peel
    Andelkovi, Darko
    Brankovic, Milica
    Kocic, Gordana
    Mitic, Sanja
    Pavlovic, Radmila
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (01)
  • [48] GC-MS analysis of bisphenol A in human placental and fetal liver samples
    Zhang, Jie
    Cooke, Gerard M.
    Curran, Ivan H. A.
    Goodyer, Cynthia G.
    Cao, Xu-Liang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (02): : 209 - 214
  • [49] Analytical development for analysis of pharmaceuticals in water samples by SPE and GC-MS
    Togola, Anne
    Budzinski, Helene
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (03) : 627 - 635
  • [50] Simultaneous Analysis of Natural Free Estrogens and Their Conjugates in Wastewater by GC-MS
    Liu, Ze-Hua
    Hashimoto, Takeshi
    Okumura, Yoichi
    Kanjo, Yoshinori
    Mizutani, Satoshi
    CLEAN-SOIL AIR WATER, 2010, 38 (02) : 181 - 188