Simultaneous Analysis of 10 Priority PAHs in Iranian Sangak Bread Samples by Developing a GC-MS Method

被引:5
|
作者
Peiravian, Farzad [1 ]
Shakoori, Attaollah [2 ]
Moradi, Vahideh [2 ]
Salamzadeh, Jamshid [3 ]
Mahboubi, Arash [4 ]
机构
[1] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmacoecon & Pharma Management, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Food & Drugs Affairs, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Food Safety Res Ctr, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Pharmaceut, Tehran, Iran
来源
IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH | 2021年 / 20卷 / 02期
关键词
GC-MS; Poly Aromatic Hydrocarbons (PAHs); Sangak bread; Iran; POLYCYCLIC AROMATIC-HYDROCARBONS; PESTICIDE-RESIDUES; MASS-SPECTROMETRY; DIETARY EXPOSURE; EXTRACTION; FOOD; INJECTION;
D O I
10.22037/ijpr.2020.113074.14097
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Human exposure to polycyclic aromatic hydrocarbons (PAHs) is known as a carcinogen risk factor. In this study, a gas chromatography-mass spectrometry (GC-MS) technique combined with the QuEChERS extraction method was developed for concurrent analysis of 10 polycyclic aromatic hydrocarbons (PAHs) in Iranian traditional Sangak bread samples. The method was validated by determining different parameters, including; linearity, accuracy, precision, limit of detection (LOD) and limit of quantitation (LOQ). Calibration curves showed a linear relationship in the concentration range of 10-500 ng/g with a coefficient of determination (R-2) ranged between 0.994 and 0.999. The obtained mean recoveries were 92-106% with the relative standard deviations (RSDs) in the range of 3-7% with an acceptable precision (RSD < 20%). The Limit of detections (LODs) for different PAHs were between 0.14-0.78 ng/g, while the limit of quantitation (LOQ) was 0.46-2.60 ng/g. Matrix effect studies showed that the analytes concluded signal suppressions or enhancements. Therefore, spiked calibration curves were used for overcoming this issue. The result of Sangak bread samples analysis using the validated method showed that 9 (19.4%) out of 47 Sangak bread samples were contaminated with phenanthrene (PHE) and anthracene (ANT) at the mean level of 10.08 +/- 6.38 ng/g which were higher than the permissible limit of European Commission regulatory control value for BaP (1 mu g/kg of wet weight) in processed cereal-based foods and baby foods for infants and young children.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 50 条
  • [21] Development of GC-MS/MS Method for Simultaneous Estimation of Four Nitrosoamine Genotoxic Impurities in Valsartan
    Tummala, Sambasiva Rao
    Amgoth, Krishnamanjari Pawar
    TURKISH JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 19 (04) : 455 - 461
  • [22] Comparison of enzymatic and GC-MS/MS analysis of creatinine in urine samples
    Ferenczy, Viktoria
    Kotora, Peter
    Hudecova, Dusana
    Blasko, Jaroslav
    Kubinec, Robert
    Behulova, Darina
    PROCEEDINGS OF THE 11TH INTERNATIONAL STUDENTS CONFERENCE "MODERN ANALYTICAL CHEMISTRY", 2015, : 7 - 11
  • [23] Development and validation of a HS/GC-MS method for the simultaneous analysis of diacetyl and acetylpropionyl in electronic cigarette refills
    Barhdadi, Sophia
    Canfyn, Michael
    Courselle, Patricia
    Rogiers, Vera
    Vanhaecke, Tamara
    Deconinck, Eric
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 142 : 218 - 224
  • [24] A Simple HS-SPME/GC-MS Method for Determination of Acrolein from Sourdough to Bread
    Drakula, Sasa
    Novotni, Dubravka
    Mustac, Nikolina Cukelj
    Voucko, Bojana
    Krpan, Marina
    Hruskar, Mirjana
    Curic, Duska
    FOOD ANALYTICAL METHODS, 2019, 12 (11) : 2582 - 2590
  • [25] The analysis of aminoazaarenes as their derivatives with GC-MS method in the heat-processed meat samples
    Janoszka, B
    Blaszczyk, U
    Warzecha, L
    Luks-Betlej, K
    Strózyk, M
    CHEMIA ANALITYCZNA, 2003, 48 (04): : 707 - 721
  • [26] Improved sample preparation and GC-MS analysis of priority organic pollutants
    Polyakova, Olga V.
    Mazur, Dmitry M.
    Lebedev, Albert T.
    ENVIRONMENTAL CHEMISTRY LETTERS, 2014, 12 (03) : 419 - 427
  • [27] Rapid and sensitive method for the simultaneous determination of PAHs and alkyl-PAHs in scrubber water using HS-SPME-GC-MS/MS
    Garcia-Gomez, Elisa
    Insa, Sara
    Gros, Meritxell
    Petrovic, Mira
    METHODSX, 2024, 12
  • [28] Method for the simultaneous analysis of 300 pesticide residues in hair by LC-MS/MS and GC-MS/MS, and its application to biomonitoring of agricultural workers
    Park, Eunyoung
    Lee, Jiho
    Lee, Junghak
    Lee, Jonghwa
    Lee, Hye Suk
    Shin, Yongho
    Kim, Jeong-Han
    CHEMOSPHERE, 2021, 277
  • [29] Synthesis of emerging cathinones and validation of a SPE GC-MS method for their simultaneous quantification in blood
    Julio, Sara
    Ferro, Raquel A.
    Santos, Susana
    Alexandre, Andrea
    Caldeira, Maria Joao
    Franco, Joao
    Barroso, Mario
    Gaspar, Helena
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (04) : 571 - 589
  • [30] A GC-MS method for the determination of polar organic compounds in atmospheric samples
    Limbeck, A
    Puxbaum, H
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1999, 73 (04) : 329 - 343