Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: Biomechanical comparison with a volar locking plate

被引:11
作者
Strauss, Eric J. [1 ]
Banerjee, Devraj [1 ]
Kummer, Frederick J. [1 ]
Tejwani, Nirmal C. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthoped Surg, New York, NY 10003 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2008年 / 64卷 / 04期
关键词
biomechanics; distal radius fracture; external fixation; volar locked plate;
D O I
10.1097/TA.0b013e3180eea9f0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. Methods: A simulated, unstable, extra-articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator (Mirza Cross Pin Fixator (CPX), A.M. Surgical Inc. Smithtown, NY] and the other was treated with a volar locked plate [Distal Volar Radial Plate (DVR), Hand Innovations, Miami, FL]. Each specimen was axially loaded in central, dorsal, and volar locations, loaded in cantilever bending in volar to dorsal, dorsal to volar, and radial to ulnar directions and loaded in torsion. Load-displacement curves were generated to determine the construct stiffness for each loading schema, with comparisons made between the two treatment groups. Specimens were then cyclically loaded with 50 N axial loads applied for 1,000 and 10,000 cycles. Measurement of construct stiffness was repeated and comparisons made both between the two treatments and within treatments to their precycling stiffness. Results: There was no significant difference in the mechanical stiffness of the nonspanning external fixator and the volar locking plate after axial loading in any of the loading modalities. Cyclic loads of 1,000 and 10,000 cycles resulted in no significant difference in construct stiffness between the nonspanning external fixator and volar locked plate. However, the nonspanning external fixator demonstrated decreasing stiffness after cyclic loading with 10,000 cycles (p < 0.02). Conclusion: This study demonstrated no significant difference in the mechanical stiffness of the CPX nonspanning external fixator and volar locked plate in a cadaveric fracture model. Both constructs appear to be biomechanically equivalent in this experimental model; however, this is only one factor in the choice of fixation device for the management of unstable distal radius fractures.
引用
收藏
页码:975 / 981
页数:7
相关论文
共 22 条
  • [1] Pin-tract complications in external fixation of fractures of the distal radius
    Ahlborg, HG
    Josefsson, PO
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (02): : 116 - 118
  • [2] [Anonymous], 2003, COCHRANE DB SYST REV
  • [3] ARO HT, 1993, HAND CLIN, V9, P531
  • [4] Bednar DA, 2004, CAN J SURG, V47, P426
  • [5] THE RESULTS OF EXTERNAL FIXATION OF THE RADIUS IN THE TREATMENT OF COMMINUTED INTRAARTICULAR FRACTURES OF THE DISTAL END
    BISHAY, M
    AGUILERA, X
    GRANT, J
    DUNKERLEY, DR
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1994, 19B (03) : 378 - 383
  • [6] Osteosynthesis of distal radial fractures with a volar locking screw plate system
    Drobetz, H
    Kutscha-Lissberg, E
    [J]. INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) : 1 - 6
  • [7] Dunning CE, 1999, J HAND SURG-AM, V24A, P992
  • [8] Should anatomic reduction be pursued in distal radial fractures?
    Fernandez, DL
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06) : 523 - 527
  • [9] The radio-radial external fixator in the treatment of fractures of the distal radius
    Fischer, T
    Koch, P
    Saager, C
    Kohut, GN
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1999, 24B (05) : 604 - 609
  • [10] Nonbridging external fixation in the treatment of unstable fractures of the distal forearm
    Flinkkilä, T
    Ristiniemi, J
    Hyvönen, P
    Hämäläinen, M
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2003, 123 (07) : 349 - 352