Time-resolved laser scanning microscopy with FLIM and advanced FCS capability

被引:2
作者
Krämer, B [1 ]
Koberling, F [1 ]
Ortmann, U [1 ]
Wahl, M [1 ]
Kapusta, P [1 ]
Bülter, A [1 ]
Erdmann, R [1 ]
机构
[1] PicoQuant GmbH, D-12489 Berlin, Germany
来源
Multiphoton Microscopy in the Biomedical Sciences V | 2005年 / 5700卷
关键词
fluorescence lifetime imaging; picosecond diode laser; confocal laser scanning microscope; time-correlated single photon counting; fluorescence correlation spectroscopy;
D O I
10.1117/12.590500
中图分类号
TH742 [显微镜];
学科分类号
摘要
We present the technical integration of state-of-the-art picosecond diode laser sources and data acquisition electronics in conventional laser scanning microscopes. This procedure offers users of laser scanning microscopes an easy upgrade path towards time-resolved measurements. Our setup uses picosecond diode lasers from 375 to 800 nm for excitation which are coupled to the microscope via a single mode fiber. The corresponding emission is guided to a fibre coupled photon counting detector, such as Photomultiplier Tubes (PMT) or Single Photon Avalanche Diodes (SPAD). This combines the outstanding sensitivity of photon counting detectors with the ease of use of diode laser sources, to allow time-resolved measurements of fluorescence decays with resolutions down to picoseconds. The synchronization signals from the laser scanning microscope are fed into the data stream recorded by the TimeHarp 200 TCSPC system, via the unique Time-Tagged Time-Resolved (TTTR) data acquisition mode. In this TTTR data acquisition mode each photon is recorded individually with its specific parameters as detector channel, picosecond timing, global arrival time and, in this special application, up to three additional markers. These markers, in combination with the global arrival time, allow the system software to reconstruct the complete image and subsequently create the full fluorescence lifetime image (FLIM). The multi-parameter data acquisition scheme of the TimeHarp 200 electronics not only records each parameter individually, but offers in addition the opportunity to analyse the parameter dependencies in a multitude of different ways. This method allows for example to calculate the fluorescence fluctuation correlation function (FCS) on any single spot of interest but also to reconstruct the fluorescence decay of each image pixel and detector channel for advanced Forster Resonance Energy Transfer (FRET) analysis. In this paper, we present some selected results acquired with standard laser scanning microscopes upgraded towards temporal resolution.
引用
收藏
页码:138 / 143
页数:6
相关论文
共 3 条
[1]  
BENDA A, 2005, IN PRESS REV SCI I R
[2]   Time-resolved fluorescence correlation spectroscopy [J].
Böhmer, M ;
Wahl, M ;
Rahn, HJ ;
Erdmann, R ;
Enderlein, J .
CHEMICAL PHYSICS LETTERS, 2002, 353 (5-6) :439-445
[3]   Aminophospholipids have no access to the luminal side of the biliary canaliculus -: Implications for the specific lipid composition of the bile fluid [J].
Tannert, A ;
Wüstner, D ;
Bechstein, J ;
Müller, P ;
Devaux, PF ;
Herrmann, A .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2003, 278 (42) :40631-40639