Optical Diagnostics for High-Voltage Tests in MITICA

被引:1
|
作者
Aprile, Daniele [1 ]
Chitarin, G. [2 ]
Lotto, L. [1 ]
Fincato, M. [1 ]
Patton, T. [1 ]
Pilan, N. [1 ]
Valente, M. [1 ]
机构
[1] Consorzio RFX, I-35127 Padua, Italy
[2] Univ Padua, Dept Engn & Management, I-36100 Padua, Italy
关键词
NBI; nuclear fusion; optical diagnostics;
D O I
10.1109/TPS.2022.3177781
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The Neutral Beam Test Facility (NBTF), Padua, Italy, is a facility devoted to the test and optimization of the Neutral Beam (NB) Injector for ITER. A full-scale prototype, called MITICA, is under construction at NBTF and has to demonstrate all the design parameters for ITER, among which a stable beam operation at the energy of 1 MeV. To test and optimize the stable high voltage holding of 1 MV, a dedicated campaign is foreseen for 2022-2023, utilizing realistic mockups of MITICA ion source and accelerator. During the campaign, the mockup of the ion source will be biased with an increasing potential up to -1 MV and the discharge toward the grounded electrodes will be observed. In this way, possible weak points of the geometry will be detected and possibly mitigated. As diagnostics for arc discharge position and intensity, a system of cameras was designed, including visible cameras, high-speed camera, and IR camera, placed on the available viewports of beam source vessel, and pointed toward the areas with higher probability of electric discharge. The results of this optical diagnostics will be then compared with the electric measurements of the discharges taken on a dedicated ground electrode, for a cross check. This article describes the motivations of the choice of the type and number of diagnostic cameras adopted during the experiments, the optimization of their layout, which includes also the use of mirrors, and the design of mechanical supports.
引用
收藏
页码:3922 / 3927
页数:6
相关论文
共 50 条
  • [1] Electrical diagnostics for high voltage tests in MITICA
    Patton, T.
    Aprile, D.
    Boldrin, M.
    Chitarin, G.
    Dan, M.
    Gobbo, R.
    Pilan, N.
    Pomaro, N.
    Rigoni, A.
    Valente, M.
    Zanotto, L.
    Barbato, P.
    Fincato, M.
    Ghiraldelli, R.
    Lotto, L.
    Molon, F.
    Tollin, M.
    FUSION ENGINEERING AND DESIGN, 2023, 192
  • [2] APPLICATION OF OPTICAL DIAGNOSTICS IN HIGH-VOLTAGE ENGINEERING
    KOLASZEWSKI, A
    SIEROTA, A
    ZDANOWICZ, L
    OPTICA APPLICATA, 1984, 14 (03) : 307 - 331
  • [3] HIGH-VOLTAGE DISCHARGES - DIAGNOSTICS AND OPPORTUNITIES
    SCHEELINE, A
    PROGRESS IN ANALYTICAL ATOMIC SPECTROSCOPY, 1984, 7 (01): : 21 - 65
  • [4] HIGH-VOLTAGE DISCHARGES - DIAGNOSTICS AND OPPORTUNITIES
    SCHEELINE, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 186 (AUG): : 168 - ANYL
  • [5] The Study of Active Atoms in High-Voltage Pulsed Coronal Discharge by Optical Diagnostics
    刘峰
    王文春
    王素
    任春生
    王友年
    Plasma Science & Technology, 2005, (03) : 2851 - 2855
  • [6] The study of active atoms in high-voltage pulsed coronal discharge by optical diagnostics
    Liu, F
    Wang, WC
    Wang, S
    Ren, CS
    Wang, YN
    PLASMA SCIENCE & TECHNOLOGY, 2005, 7 (03) : 2851 - 2855
  • [7] Complex Diagnostics of Defects in High-Voltage Insulators
    Golenishchev-Kutuzov A.V.
    Golenishchev-Kutuzov V.A.
    Ivanov D.A.
    Mardanov G.D.
    Semennikov A.V.
    Van’kov Y.V.
    Bulletin of the Russian Academy of Sciences: Physics, 2019, 83 (12) : 1490 - 1493
  • [8] Gas chromatography for diagnostics of high-voltage equipment
    Arakelyan, V.G.
    Elektrotekhnika, 1994, (02): : 8 - 17
  • [9] NONDESTRUCTIVE TESTING IN DIAGNOSTICS OF HIGH-VOLTAGE VARISTORS
    Hasse, Lech
    Smulko, Janusz
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 1354 - 1358
  • [10] Accelerated diagnostics of high-voltage circuit breakers
    Mikheev G.M.
    Fedorov Yu.A.
    Shevtsov V.M.
    Batalygin S.N.
    Russian Electrical Engineering, 2007, 78 (12) : 649 - 657