Involvement of Cu(II) in the electrocatalytic reduction of bromate on a disposable nano-copper oxide modified screen-printed carbon electrode: hair waving products as an example

被引:17
作者
Chen, Pei-Yen [1 ]
Yang, Hsueh-Hui [2 ,3 ]
Huang, Chien-Chang [4 ]
Chen, Yu-Hsuan [4 ]
Shih, Ying [4 ]
机构
[1] Cardinal Tien Jr Coll Healthcare & Management, Dept Hlth & Beauty, New Taipei City 231, Taiwan
[2] Buddhist Tzu Chi Gen Hosp, Dept Med Res, Hualien 970, Taiwan
[3] Tzu Chi Coll Technol, Gen Educ Ctr, Hualien 970, Taiwan
[4] Providence Univ, Dept Cosmet Sci, Taichung 433, Taiwan
关键词
copper; bromate; hair waving products; screen-printed carbon electrode; FLOW-INJECTION ANALYSIS; LIQUID-CHROMATOGRAPHY; AMPEROMETRIC SENSOR; CERAMIC ELECTRODE; POTASSIUM BROMATE; DRINKING WATERS; NANOTUBES; PERFORMANCE; FILM; NANOPARTICLES;
D O I
10.1016/j.electacta.2015.02.060
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A disposable nano-copper oxide modified screen-printed carbon electrode (CuOSPCE) was developed as a quick and convenient method to identify the bromate content in hair waving products. The electrode was prepared via electrodeposition of copper ions on a bare screen-printed carbon electrode (SPCE). It was demonstrated that the nano-copper oxide on the SPCEs could significantly enhance the electrochemical reduction of bromate in weak acidic solutions. The analytical results indicate that CuOSPCE coupling with a flow injection analysis (FIA) system (CuOSPCE/FIA) is a sensitive method for the determination of the bromate. A wide linear range from 0.01 to 300 mgL(-1) (66.27 to 1.99 x 106 nmol L-1) was observed, and a detection limit of 3.5 mu g L-1 (23.19 nmol L-1) (DL, S/N = 3) was calculated. The results also indicated that both the sensitivity and the response time of CuOSPCE/FIA toward bromate were not affected by several anions. Furthermore, the CuOSPCE/FIA demonstrated extremely high recovery, ranging from 98.45% to 103.89%, as well as good accuracy compared to the results obtained by a standard iodometric method. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 107
页数:8
相关论文
共 38 条
[11]   Vacancy-Mediated Magnetism in Pure Copper Oxide Nanoparticles [J].
Gao, Daqiang ;
Zhang, Jing ;
Zhu, Jingyi ;
Qi, Jing ;
Zhang, Zhaohui ;
Sui, Wenbo ;
Shi, Huigang ;
Xue, Desheng .
NANOSCALE RESEARCH LETTERS, 2010, 5 (04) :769-772
[12]  
Geter David R, 2006, Transl Oncogenomics, V1, P33
[13]   Bromate determination in water after membrane complexation and total reflection X-ray fluorescence analysis [J].
Hatzistavros, Vasilios S. ;
Koulouridakis, Pavlos E. ;
Aretaki, Ioanna I. ;
Kallithrakas-Kontos, Nikolaos G. .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :2827-2832
[14]  
International Organization for Standardization, 112062011 ISO CENTR
[15]   X-ray photoelectron spectroscopy (XPS) and magnetic susceptibility studies of copper-vanadium phosphate glasses [J].
Khattak, GD ;
Salim, MA ;
Wenger, LE ;
Gilani, AH .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2000, 262 (1-3) :66-79
[16]   TOXICITY AND CARCINOGENICITY OF POTASSIUM BROMATE - A NEW RENAL CARCINOGEN [J].
KUROKAWA, Y ;
MAEKAWA, A ;
TAKAHASHI, M ;
HAYASHI, Y .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1990, 87 :309-335
[17]   Synthesis of silver/multi-walled carbon nanotubes composite and its application for electrocatalytic reduction of bromate [J].
Li, Qin ;
Zhang, Qiu ;
Ding, Liang ;
Zhou, Dandan ;
Cui, Hao ;
Wei, Zhongbo ;
Zhai, Jianping .
CHEMICAL ENGINEERING JOURNAL, 2013, 217 :28-33
[18]   Electrochemical Reduction of Bromate by a Pd Modified Carbon Fiber Electrode: Kinetics and Mechanism [J].
Mao, Ran ;
Zhao, Xu ;
Qu, Jiuhui .
ELECTROCHIMICA ACTA, 2014, 132 :151-157
[19]   FAD-modified SiO2/ZrO2/C ceramic electrode for electrocatalytic reduction of bromate and iodate [J].
Marafon, Eduardo ;
Kubota, Lauro T. ;
Gushikem, Yoshitaka .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (03) :377-383
[20]  
National Toxicology Program U.S. National Institutes of Health, TOX STUD SOD BROM CA