Performance Assessment of Low-Temperature A-CAES (Adiabatic Compressed Air Energy Storage) Plants

被引:17
作者
Tola, Vittorio [1 ]
Marcello, Francesca Carolina [1 ]
Cocco, Daniele [1 ]
Cau, Giorgio [1 ]
机构
[1] Univ Cagliari, Dept Mech Chem & Mat Engn, I-09123 Cagliari, Italy
关键词
compressed air energy storage; low temperature A-CAES; Thermal Energy Storage; system integration; HEAT-TRANSFER; SYSTEM; POWER; OPTIMIZATION; SIMULATION; EXPANSION;
D O I
10.1007/s11630-022-1632-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
The widespread diffusion of renewable energy sources calls for the development of high-capacity energy storage systems as the A-CAES (Adiabatic Compressed Air Energy Storage) systems. In this framework, low temperature (100 degrees C-200 degrees C) A-CAES (LT-ACAES) systems can assume a key role, avoiding some critical issues connected to the operation of high temperature ones. In this paper, two different LT-ACAES configurations are proposed. The two configurations are characterized by the same turbomachines and compressed air storage section, while differ in the TES section and its integration with the turbomachinery. In particular, the first configuration includes two separated cycles: the working fluid (air) cycle and the heat transfer fluid (HTF) cycle. Several heat exchangers connect the two cycles allowing to recover thermal energy from the compressors and to heat the compressed air at the turbine inlet. Two different HTFs were considered: air (case A) and thermal oil (case B). The second configuration is composed of only one cycle, where the operating fluid and the HTF are the same (air) and the TES section is composed of three different packed-bed thermal storage tanks (case C). The tanks directly recover the heat from the compressors and heat the air at each turbine inlet, avoiding the use of heat exchangers. The LT-ACAES systems were modelled and simulated using the ASPEN-Plus and the MATLAB-Simulink environments. The main aim of this study was the detailed analysis of the reciprocal influence between the turbomachinery and the TES system; furthermore, the performance evaluation of each plant was carried out assuming both on-design and off-design operating conditions. Finally, the different configurations were compared through the main performance parameters, such as the round-trip efficiency. A total power output of around 10 MW was set, leading to a TES tank volume ranging between 500 and 700 m(3). The second configuration with three TES systems appears to be the most promising in terms of round-trip efficiency since the energy produced during the discharging phase is greater. In particular, the round-trip efficiency of the LT-ACAES ranges between 0.566 (case A) to 0.674 (case C). Although the second configuration assures the highest performance, the effect of operating at very high pressures inside the tanks should be carefully evaluated in terms of overall costs.
引用
收藏
页码:1279 / 1292
页数:14
相关论文
共 33 条
[1]   An overview of thermal energy storage systems [J].
Alva, Guruprasad ;
Lin, Yaxue ;
Fang, Guiyin .
ENERGY, 2018, 144 :341-378
[2]   Overview of energy storage in renewable energy systems [J].
Amrouche, S. Ould ;
Rekioua, D. ;
Rekioua, T. ;
Bacha, S. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (45) :20914-20927
[3]  
[Anonymous], 2014, IEA REPORT
[4]  
[Anonymous], Renewable Power
[5]   Adiabatic Compressed Air Energy Storage with packed bed thermal energy storage [J].
Barbour, Edward ;
Mignard, Dimitri ;
Ding, Yulong ;
Li, Yongliang .
APPLIED ENERGY, 2015, 155 :804-815
[6]  
Brown R.N., 2005, COMPRESSORS SELECTIO
[7]   Experimental investigation of cycling behaviour of pilot-scale thermal oil packed-bed thermal storage system [J].
Bruch, A. ;
Molina, S. ;
Esence, T. ;
Fourmigue, J. F. ;
Couturier, R. .
RENEWABLE ENERGY, 2017, 103 :277-285
[8]   A review on compressed air energy storage: Basic principles, past milestones and recent developments [J].
Budt, Marcus ;
Wolf, Daniel ;
Span, Roland ;
Yan, Jinyue .
APPLIED ENERGY, 2016, 170 :250-268
[9]   Comparison between experimental and numerical results of a packed-bed thermal energy storage system in continuous operation [J].
Cascetta, Mario ;
Serra, Fabio ;
Cau, Giorgio ;
Puddu, Pierpaolo .
ATI 2018 - 73RD CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, 2018, 148 :234-241
[10]   Numerical investigation of a packed bed thermal energy storage system with different heat transfer fluids [J].
Cascetta, Mario ;
Cau, Giorgio ;
Puddu, Pierpaolo ;
Serra, Fabio .
ATI 2013 - 68TH CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, 2014, 45 :598-607