Safety and efficacy of zero fluoroscopy transseptal puncture with different approaches

被引:48
作者
Baykaner, Tina [1 ]
Quadros, Kenneth K. [2 ]
Thosani, Amit [3 ]
Yasmeh, Babak [5 ]
Mitra, Raman [4 ]
Liu, Emerson [3 ]
Belden, William [3 ]
Liu, Zhigang [5 ]
Costea, Alex [5 ]
Brodt, Chad R. [1 ]
Zei, Paul C. [2 ]
机构
[1] Stanford Univ, Dept Med, Stanford, CA 94305 USA
[2] Brigham & Womens Hosp, Dept Med, 75 Francis St, Boston, MA 02115 USA
[3] Allegheny Hlth Network, Cardiovasc Inst, Pittsburgh, PA USA
[4] Beacon Hlth Syst, Dept Med, South Bend, IN USA
[5] Univ Cincinnati, Dept Med, Cincinnati, OH USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2020年 / 43卷 / 01期
基金
美国国家卫生研究院;
关键词
fluoroscopy reduction; low fluoroscopy; transseptal puncture; zero-fluoroscopy; PULMONARY VEIN ISOLATION; ATRIAL-FIBRILLATION; CATHETER ABLATION; RADIATION; PROTECTION; EXPERIENCE; REDUCTION;
D O I
10.1111/pace.13841
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Atrial fibrillation (AF) ablation requires access to the left atrium (LA) via transseptal puncture (TP). TP is traditionally performed with fluoroscopic guidance. Use of intracardiac echocardiography (ICE) and three-dimensional mapping allows for zero fluoroscopy TP. Objective To demonstrate safety and efficacy of zero fluoroscopy TP using multiple procedural approaches. Methods Patients undergoing AF ablation between January 2015 and November 2017 at five institutions were included. ICE and three-dimensional mapping were used for sheath positioning and TP. Variable technical approaches were used across centers including placement of J wire in the superior vena cava with ICE guidance followed by dragging down the transseptal sheath into the interatrial septum, or guiding the transseptal sheath directly to the interatrial septum by localizing the ablation catheter with three-dimensional mapping and replacing it with the transseptal needle once in position. In patients with pacemaker/implantable cardiac defibrillator leads, pre-/poststudy device interrogation was performed. Results A total of 747 TPs were performed (646 patients, age 63.1 +/- 13.1, 67.5% male, LA volume index 34.5 +/- 15.8 mL/m(2), ejection fraction 57.7 +/- 10.9%) with 100% success. No punctures required fluoroscopy. Two pericardial effusions, two pericardial tamponades requiring pericardiocentesis, and one transient ischemic attack were observed during the overall ablation procedure, with a total complication rate of 0.7%. There were no other periprocedural complications related to TP, including intrathoracic bleeding, stroke, or death both immediately following TP and within 30 days of the procedure. In patients with intracardiac devices, no device-related complications were observed. Conclusion TP can be safely and effectively performed without the need for fluoroscopy.
引用
收藏
页码:12 / 18
页数:7
相关论文
共 23 条
[1]  
Al-Khatib SM, 2018, CIRCULATION, V138, pE210, DOI [10.1161/CIR.0000000000000549, 10.1161/CIR.0000000000000548]
[2]  
[Anonymous], 2015, CIRCULATION, DOI DOI 10.1016/j.jacc.2015.08.856
[3]   Fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report [J].
Balmforth, Damian Charles ;
Smith, Andrew ;
Schilling, Richard ;
O'Brien, Ben .
EUROPEAN HEART JOURNAL-CASE REPORTS, 2018, 2 (04)
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Catheter Ablation of Atrial Fibrillation Using Zero-Fluoroscopy Technique: A Randomized Trial [J].
Bulava, Alan ;
Hanis, Jiri ;
Eisenberger, Martin .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (07) :797-806
[6]  
Calkins H, 2017, HEART RHYTHM, V14, pE445, DOI [10.1016/j.hrthm.2017.07.009, 10.1093/europace/eux275, 10.1016/j.hrthm.2017.05.012]
[7]   Fluoroscopy integrated 3D mapping significantly reduces radiation exposure during ablation for a wide spectrum of cardiac arrhythmias [J].
Christoph, Marian ;
Wunderlich, Carsten ;
Moebius, Stefanie ;
Forkmann, Mathias ;
Sitzy, Judith ;
Salmas, Jozef ;
Mayer, Julia ;
Huo, Yan ;
Piorkowski, Christopher ;
Gaspar, Thomas .
EUROPACE, 2015, 17 (06) :928-937
[8]  
COPE C, 1959, J THORAC SURG, V37, P482
[9]   Evaluation of a radiation protection cabin for invasive electrophysiological procedures [J].
Dragusin, Octavian ;
Weerasooriya, Rukshen ;
Jais, Pierre ;
Hocini, Meleze ;
Ector, Joris ;
Takahashi, Yoshihide ;
Haissaguerre, Michel ;
Bosmans, Hilde ;
Heidbuchel, Hein .
EUROPEAN HEART JOURNAL, 2007, 28 (02) :183-189
[10]   Obesity is a major determinant of radiation dose in patients undergoing pulmonary vein isolation for atrial fibrillation [J].
Ector, Joris ;
Dragusin, Octavian ;
Adriaenssens, Bert ;
Huybrechts, Wim ;
Willems, Rik ;
Ector, Hugo ;
Heidbuechel, Hein .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (03) :234-242