Correction of Pelvic Tilt and Pelvic Rotation in Cup Measurement after THA - An Experimental Study

被引:15
作者
Schwarz, Timo Julian [1 ]
Weber, Markus [1 ]
Dornia, Christian [2 ]
Worlicek, Michael [1 ]
Renkawitz, Tobias [1 ]
Grifka, Joachim [1 ]
Craiovan, Benjamin [1 ]
机构
[1] Univ Med Ctr Regensburg, Dept Orthoped Surg, Kaiser Karl V Allee 3, D-93077 Bad Abbach, Germany
[2] Univ Med Ctr, Dept Radiol, Regensburg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2017年 / 189卷 / 09期
关键词
THA; pelvic tilt; pelvic rotation; anteversion; cup position; inclination; TOTAL HIP-ARTHROPLASTY; ACETABULAR CUP; PLAIN ANTEROPOSTERIOR; ORIENTATION; ANTEVERSION; COMPONENT; RELIABILITY; VALIDITY; VERSION; MISINTERPRETATION;
D O I
10.1055/s-0043-110012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Accurate assessment of cup orientation on postoperative pelvic radiographs is essential for evaluating outcome after THA. Here, we present a novel method for correcting measurement inaccuracies due to pelvic tilt and rotation. Method In an experimental setting, a cup was implanted into a dummy pelvis, and its final position was verified via CT. To show the effect of pelvic tilt and rotation on cup position, the dummy was fixed to a rack to achieve a tilt between +15 degrees anterior and -15 degrees posterior and 0 degrees to 20 degrees rotation to the contralateral side. According to Murray's definitions of anteversion and inclination, we created a novel corrective procedure to measure cup position in the pelvic reference frame (anterior pelvic plane) to compensate measurement errors due to pelvic tilt and rotation. Results The cup anteversion measured on CT was 23.3 degrees; on AP pelvic radiographs, however, variations in pelvic tilt (+/- 15 degrees) resulted in anteversion angles between 11.0 degrees and 36.2 degrees (mean error 8.3 degrees +/- 3.9 degrees). The cup inclination was 34.1 degrees on CT and ranged between 31.0 degrees and 38.7 degrees (m.e. 2.3 degrees +/- 1.5 degrees) on radiographs. Pelvic rotation between 0 degrees and 20 degrees showed high variation in radiographic anteversion (21.2 degrees-31.2 degrees, m.e. 6.0 degrees +/- 3.1 degrees) and inclination (34.1 degrees-27.2 degrees, m.e. 3.4 degrees +/- 2.5 degrees). Our novel correction algorithm for pelvic tilt reduced the mean error in anteversion measurements to 0.6 degrees +/- 0.2 degrees and in inclination measurements to 0.7 degrees (SD +/- 0.2). Similarly, the mean error due to pelvic rotation was reduced to 0.4 degrees +/- 0.4 degrees for anteversion and to 1.3 degrees +/- 0.8 for inclination. Conclusion Pelvic tilt and pelvic rotation may lead to misinterpretation of cup position on anteroposterior pelvic radiographs. Mathematical correction concepts have the potential to significantly reduce these errors, and could be implemented in future radiological software tools.
引用
收藏
页码:864 / 873
页数:10
相关论文
共 36 条
[1]   ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]   The rationale for tilt-adjusted acetabular cup navigation [J].
Babisch, Juergen W. ;
Layher, Frank ;
Amiot, Louis-Philippe .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (02) :357-365
[3]   Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate? [J].
Craiovan, Benjamin ;
Renkawitz, Tobias ;
Weber, Markus ;
Grifka, Joachim ;
Nolte, Lutz ;
Zheng, Guoyan .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (10) :2009-2015
[4]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[5]   Correction of acetabular cup orientation measurements for X-ray beam offset [J].
Derbyshire, Brian .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (09) :1119-1126
[6]   CT Outperforms Radiography for Determination of Acetabular Cup Version after THA [J].
Ghelman, Bernard ;
Kepler, Christopher K. ;
Lyman, Stephen ;
Della Valle, Alejandro Gonzalez .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) :2362-2370
[7]   Pelvic orientation and assessment of hip dysplasia in adults [J].
Jacobsen, S ;
Sonne-Holm, S ;
Lund, B ;
Soballe, K ;
Kiær, T ;
Rovsing, H ;
Monrad, H .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06) :721-729
[8]   Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement [J].
Kalteis, T ;
Handel, M ;
Herold, T ;
Perlick, L ;
Paetzel, C ;
Grifka, J .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (02) :294-300
[9]   Pelvic tilt makes acetabular cup navigation inaccurate [J].
Lembeck, B ;
Mueller, O ;
Reize, P ;
Wuelker, N .
ACTA ORTHOPAEDICA, 2005, 76 (04) :517-523
[10]   The faux profil (oblique view) of the hip in the standing position. Contribution to the evaluation of osteoarthritis of the adult hip [J].
Lequesne, MG ;
Laredo, JD .
ANNALS OF THE RHEUMATIC DISEASES, 1998, 57 (11) :676-681