Cobalt deposition in mineralized bone tissue after metal-on-metal hip resurfacing: Quantitative -X-ray-fluorescence analysis of implant material incorporation in periprosthetic tissue

被引:6
作者
Hahn, Michael [1 ]
Busse, Bjoern [1 ]
Procop, Mathias [2 ]
Zustin, Jozef [3 ]
Amling, Michael [1 ]
Katzer, Alexander [4 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Osteol & Biomech, D-22529 Hamburg, Germany
[2] IFG Inst Sci Instruments, D-12489 Berlin, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Inst Bone Pathol, D-22529 Hamburg, Germany
[4] ORTHOCLIN Hamburg, D-22457 Hamburg, Germany
关键词
microanalysis; micro-X-ray fluorescence; metal alloys; orthopedic pathology; hip implants; FINITE-ELEMENT-ANALYSIS; CANCER-RISK; LOAD-TRANSFER; FEMORAL-HEAD; RUNNING-IN; ARTHROPLASTY; CHROMIUM; WEAR; REPLACEMENT; PARTICLES;
D O I
10.1002/jbm.b.33667
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most resurfacing systems are manufactured from cobalt-chromium alloys with metal-on-metal (MoM) bearing couples. Because the quantity of particulate metal and corrosion products which can be released into the periprosthetic milieu is greater in MoM bearings than in metal-on-polyethylene (MoP) bearings, it is hypothesized that the quantity and distribution of debris released by the MoM components induce a compositional change in the periprosthetic bone. To determine the validity of this claim, nondestructive mu-X-ray fluorescence analysis was carried out on undecalcified histological samples from 13 femoral heads which had undergone surface replacement. These samples were extracted from the patients after gradient time points due to required revision surgery. Samples from nonintervened femoral heads as well as from a MoP resurfaced implant served as controls. Light microscopy and mu-X-ray fluorescence analyses revealed that cobalt debris was found not only in the soft tissue around the prosthesis and the bone marrow, but also in the mineralized bone tissue. Mineralized bone exposed to surface replacements showed significant increases in cobalt concentrations in comparison with control specimens without an implant. A maximum cobalt concentration in mineralized hard tissue of up to 380 ppm was detected as early as 2 years after implantation. Values of this magnitude are not found in implants with a MoP surface bearing until a lifetime of more than 20 years. This study demonstrates that hip resurfacing implants with MoM bearings present a potential long-term health risk due to rapid cobalt ion accumulation in periprosthetic hard tissue. (c) 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1855-1862, 2017.
引用
收藏
页码:1855 / 1862
页数:8
相关论文
共 50 条
[1]  
Adams Julie E, 2003, Ann Diagn Pathol, V7, P35, DOI 10.1053/adpa.2003.50006
[2]  
Beaule Paul E, 2007, Instr Course Lect, V56, P163
[3]   Daily intake of essential minerals and metallic micropollutants from foods in France [J].
Biego, GH ;
Joyeux, M ;
Hartemann, P ;
Debry, G .
SCIENCE OF THE TOTAL ENVIRONMENT, 1998, 217 (1-2) :27-36
[4]   A new microfocus x-ray source, iMOXS, for highly sensitive XRF analysis in scanning electron microscopes [J].
Bjeoumikhov, A ;
Arkadiev, V ;
Eggert, F ;
Hodoroaba, VD ;
Langhoff, N ;
Procop, M ;
Rabe, J ;
Wedell, R .
X-RAY SPECTROMETRY, 2005, 34 (06) :493-497
[5]   Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Grübl, A ;
Jankovsky, R ;
Meisinger, V ;
Lehr, S ;
Gottsauner-Wolf, F .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :66-70
[6]   Hip resurfacing arthroplasty [J].
Buergi, Martin L. ;
Walter, William L. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (07) :61-65
[7]   Allocation of nonbirefringent wear debris: Darkfield illumination associated with PIXE microanalysis reveals cobalt deposition in mineralized bone matrix adjacent to CoCr implants [J].
Busse, B. ;
Hahn, M. ;
Niecke, M. ;
Jobke, B. ;
Pueschel, K. ;
Delling, G. ;
Katzer, A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 87A (02) :536-545
[8]   Effects of strontium ranelate administration on bisphosphonate-altered hydroxyapatite: Matrix incorporation of strontium is accompanied by changes in mineralization and microstructure [J].
Busse, B. ;
Jobke, B. ;
Hahn, M. ;
Priemel, M. ;
Niecke, M. ;
Seitz, S. ;
Zustin, J. ;
Semler, J. ;
Amling, M. .
ACTA BIOMATERIALIA, 2010, 6 (12) :4513-4521
[9]   Neurotoxicity of cobalt [J].
Catalani, S. ;
Rizzetti, M. C. ;
Padovani, A. ;
Apostoli, P. .
HUMAN & EXPERIMENTAL TOXICOLOGY, 2012, 31 (05) :421-437
[10]   Nine-Year Incidence of Kidney Disease in Patients Who Have Had Total Hip Arthroplasty [J].
Chandran, Shaun E. ;
Giori, Nicholas J. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (06) :24-27