Current topics in robotic-assisted total hip arthroplasty: a review

被引:46
作者
Perets, Itay [1 ,2 ]
Mu, Brian H. [1 ,3 ]
Mont, Michael A. [4 ,5 ]
Rivkin, Gurion [2 ]
Kandel, Leonid [2 ]
Domb, Benjamin G. [1 ]
机构
[1] Amer Hip Inst, 999 E Touhy Ave,Suite 450, Des Plaines, IL 60018 USA
[2] Hadassa Hebrew Univ Hosp, Jerusalem, Israel
[3] Rosalind Franklin Univ Med & Sci, N Chicago, IL USA
[4] Northwell Hlth, Lenox Hill Hosp, New York, NY USA
[5] Cleveland Clin, Cleveland, OH 44106 USA
关键词
Arthroplasty; robotics; STEM IMPLANTATION; MANUAL IMPLANTATION; REPLACEMENT; ACCURACY; STABILITY; SYSTEM; SCORE; WEAR; THA;
D O I
10.1177/1120700019893636
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Total hip arthroplasty (THA) is among the most successful procedures of modern medicine, yet failures and complications continue to occur, leaving room for improvement. Robotics is a cutting-edge technology that tries to improve joint arthroplasty surgery. There is some evidence that shows that robotic-assisted THA improves implant positioning, but less is known about its effect on clinical outcomes or the rate of complications. This article reviews the literature on robotic-assisted THA to elucidate the history, advantages, disadvantages, and current clinical understanding of this procedure.
引用
收藏
页码:118 / 124
页数:7
相关论文
共 47 条
[1]   Robots in orthopaedic surgery - Past, present, and future [J].
Bargar, William L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :31-36
[2]   Fourteen Year Follow-Up of Randomized Clinical Trials of Active Robotic-Assisted Total Hip Arthroplasty [J].
Bargar, William L. ;
Parise, Carol A. ;
Hankins, Andrea ;
Marlen, Natalie A. ;
Campanelli, Valentina ;
Netravali, Nathan A. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (03) :810-814
[3]  
Bargar WL, 1998, CLIN ORTHOP RELAT R, P82
[4]   Poor accuracy of freehand cup positioning during total hip arthroplasty [J].
Bosker, B. H. ;
Verheyen, C. C. P. M. ;
Horstmann, W. G. ;
Tulp, N. J. A. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) :375-379
[5]   The John Charnley Award Risk Factors for Cup Malpositioning Quality Improvement Through a Joint Registry at a Tertiary Hospital [J].
Callanan, Mark C. ;
Jarrett, Bryan ;
Bragdon, Charles R. ;
Zurakowski, David ;
Rubash, Harry E. ;
Freiberg, Andrew A. ;
Malchau, Henrik .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) :319-329
[6]   A biomechanical study on the initial stability of THR stems after manual and robot-assisted implantation in synthetic femora [J].
Decking, J ;
Gerber, A ;
Kränzlein, J ;
Meurer, A ;
Böhm, B ;
Plitz, W .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2004, 142 (03) :309-313
[7]   Leg length discrepancy after total hip arthroplasty: A review of literature [J].
Desai A.S. ;
Dramis A. ;
Board T.N. .
Current Reviews in Musculoskeletal Medicine, 2013, 6 (4) :336-341
[8]   Accuracy of Component Positioning in 1980 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of Guidance [J].
Domb, Benjamin G. ;
Redmond, John M. ;
Louis, Steven S. ;
Alden, Kris J. ;
Daley, Robert J. ;
LaReau, Justin M. ;
Petrakos, Alexandra E. ;
Gui, Chengcheng ;
Suarez-Ahedo, Carlos .
JOURNAL OF ARTHROPLASTY, 2015, 30 (12) :2208-2218
[9]   Comparison of Robotic-assisted and Conventional Acetabular Cup Placement in THA: A Matched-pair Controlled Study [J].
Domb, Benjamin G. ;
El Bitar, Youssef F. ;
Sadik, Adam Y. ;
Stake, Christine E. ;
Botser, Itamar B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (01) :329-336
[10]   Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty [J].
Gallo, Jiri ;
Havranek, Vitezslav ;
Zapletalova, Jana .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (01) :19-26