Mechanical and durability performance of sustainable structural concretes: An experimental study

被引:83
作者
Faella, Ciro [1 ]
Lima, Carmine [1 ]
Martinelli, Enzo [1 ]
Pepe, Marco [1 ]
Realfonzo, Roberto [1 ]
机构
[1] Univ Salerno, Dept Civil Engn, Via Giovanni Paolo 2 132, I-84084 Fisciano, SA, Italy
关键词
Recycled aggregate concrete; Fly ash; Durability; Water permeability; Chloride-ion penetration; Carbonation; RECYCLED AGGREGATE CONCRETE; FLY-ASH; COMPRESSIVE STRENGTH; BEHAVIOR; PERMEABILITY; CARBONATION; COARSE; CEMENT;
D O I
10.1016/j.cemconcomp.2016.05.009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study reports the results of a wide experimental campaign intended at investigating the mechanical and durability performance of structural concretes made with Recycled Concrete Aggregates (RCAs) and coal Fly Ash (FA). To this end, twelve mixtures were designed by replacing part of the ordinary constituents (i.e. cement, sand and coarse aggregates) of a reference one with RCAs and FA. Samples of these mixtures were subjected to various tests aimed at assessing both their structural properties and durability performance. As for the former, time evolution of compressive strength was monitored at various curing times up to 365 days, and the splitting strength was determined at 28 days. Moreover, the expected durability performance of the aforementioned concrete mixtures was scrutinised by measuring some relevant physical quantities, such as water permeability, carbonation depth and chloride-ions ingress at various curing ages. The results obtained from these tests are often not self-evident, as they unveil the synergistic effect of combining both RCAs and FA on the resulting physical and mechanical properties of "green" concrete. Moreover, they demonstrate that the current code restrictions on the use of both RCAs and FA for structural concrete might be significantly relaxed, especially if the delayed binder effect, induced by the latter, is duly taken into account and, hence, concrete properties are measured at curing times longer than the conventional 28 days. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:85 / 96
页数:12
相关论文
共 50 条
[1]  
[Anonymous], 1994, MATER STRUCT, V27, P557
[2]  
[Anonymous], 2012, C128 ASTM
[3]  
[Anonymous], 2013, 12620 EN
[4]  
[Anonymous], 2009, 123908 EN
[5]  
[Anonymous], 2018, GU NO 42 20 FEBBRAIO
[6]  
[Anonymous], 2011, EN 197-1 - Cement - Part 1: Composition, specifications and conformity criteria for common cements", DOI DOI 10.31030/1758792
[7]  
[Anonymous], 13242 EN
[8]  
[Anonymous], SPRINGER THESES
[9]  
[Anonymous], 2012, EN (Standard) 450-1-2012
[10]  
[Anonymous], 2019, STANDARD TEST METHOD, DOI DOI 10.1520/C1202-19.2