Reduced Scan Time Three-Dimensional FLAIR Using Modulated Inversion and Repetition Time

被引:2
作者
Gai, Neville D. [1 ]
Butman, John A. [1 ]
机构
[1] NIH, Radiol & Imaging Sci, Ctr Clin, Bethesda, MD 20892 USA
关键词
3D FLAIR; modulated repetition time; modulated inversion time; scan time reduction; variable repetition time; REFOCUSING FLIP ANGLES; SEQUENCES; OPTIMIZATION; BRAIN; TESLA; T1;
D O I
10.1002/jmri.24679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe purpose of this study is to design and evaluate a new reduced scan time three-dimensional (3D) FLuid Attenuated Inversion Recovery (FLAIR) sequence. MethodsThe 3D FLAIR sequence was modified so that the repetition time was modulated in a predetermined smooth manner (3D mFLAIR). Inversion times were adjusted accordingly to maintain cerebrospinal fluid (CSF) suppression. Simulations were performed to determine SNR for gray matter (GM), white matter (WM), and CSF. Fourteen volunteers were imaged using the modified and product sequence. SNR measurements were performed in GM, WM, and CSF. Mean value and the 95% confidence interval ([CI]) were assessed. Scan time for the 3D FLAIR and 3D mFLAIR sequences was measured. ResultsThere was no statistically significant difference in the SNR measured in GM (P value=0.5; mean SNR=42.8 [CI]: 38.2-45.5 versus 42.2 [CI]: 38.3-46.1 for 3D FLAIR and 3D mFLAIR, respectively) and WM (P value=0.25; mean SNR=32.1 [CI]: 30.3-33.8 versus 32.9 [CI]: 31.1-34.7). Scan time reduction greater than 30% was achieved for the given parameter set with the 3D mFLAIR sequence. ConclusionScan time for 3D FLAIR can be effectively reduced by modulating repetition and inversion time in a predetermined manner while maintaining the SNR and CNR of a constant TR sequence. J. Magn. Reson. Imaging 2015;41:1440-1446. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1440 / 1446
页数:7
相关论文
共 13 条
  • [1] The sensitivity of low flip angle RARE imaging
    Alsop, DC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 176 - 184
  • [2] Modulated Repetition Time Look-Locker (MORTLL): A Method for Rapid High Resolution Three-Dimensional T1 Mapping
    Gai, Neville D.
    Butman, John A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 640 - 648
  • [3] USE OF FLUID ATTENUATED INVERSION RECOVERY (FLAIR) PULSE SEQUENCES IN MRI OF THE BRAIN
    HAJNAL, JV
    BRYANT, DJ
    KASUBOSKI, L
    PATTANY, PM
    DECOENE, B
    LEWIS, PD
    PENNOCK, JM
    OATRIDGE, A
    YOUNG, IR
    BYDDER, GM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) : 841 - 844
  • [4] HIGH SIGNAL REGIONS IN NORMAL WHITE MATTER SHOWN BY HEAVILY T2-WEIGHTED CSF NULLED IR SEQUENCES
    HAJNAL, JV
    DECOENE, B
    LEWIS, PD
    BAUDOUIN, CJ
    COWAN, FM
    PENNOCK, JM
    YOUNG, IR
    BYDDER, GM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (04) : 506 - 513
  • [5] Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS)
    Hennig, J
    Weigel, M
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) : 527 - 535
  • [6] MULTIECHO IMAGING SEQUENCES WITH LOW REFOCUSING FLIP ANGLES
    HENNIG, J
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03): : 397 - 407
  • [7] MULTIPLE FIELD-STRENGTH INVIVO T1 AND T2 FOR CEREBROSPINAL-FLUID PROTONS
    HOPKINS, AL
    YEUNG, HN
    BRATTON, CB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) : 303 - 311
  • [8] Multi-parametric neuroimaging reproducibility: A 3-T resource study
    Landman, Bennett A.
    Huang, Alan J.
    Gifford, Aliya
    Vikram, Deepti S.
    Lim, Issel Anne L.
    Farrell, Jonathan A. D.
    Bogovic, John A.
    Hua, Jun
    Chen, Min
    Jarso, Samson
    Smith, Seth A.
    Joel, Suresh
    Mori, Susumu
    Pekar, James J.
    Barker, Peter B.
    Prince, Jerry L.
    van Zijl, Peter C. M.
    [J]. NEUROIMAGE, 2011, 54 (04) : 2854 - 2866
  • [9] CONTRAST OPTIMIZATION OF FLUID-ATTENUATED INVERSION-RECOVERY (FLAIR) IMAGING
    RYDBERG, JN
    RIEDERER, SJ
    RYDBERG, CH
    JACK, CR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) : 868 - 877
  • [10] High-Resolution Magnetization-Prepared 3D-FLAIR Imaging at 7.0 Tesla
    Visser, Fredy
    Zwanenburg, Jaco J. M.
    Hoogduin, Johannes M.
    Luijten, Peter R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (01) : 194 - 202