Handling Structural Plant-model Mismatch via Multi-stage Nonlinear Model Predictive Control

被引:0
作者
Subramanian, Sankaranarayanan [1 ]
Lucia, Sergio [1 ]
Engell, Sebastian [1 ]
机构
[1] TU Dortmund, Proc Dynam & Operat Grp, Dortmund, Germany
来源
2015 EUROPEAN CONTROL CONFERENCE (ECC) | 2015年
关键词
CONSTRAINED LINEAR-SYSTEMS; DISTURBANCES; UNCERTAINTY; REACTOR;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper we present an approach to deal with structural uncertainties (structure and dimension of the model are not perfectly known) in the framework of nonlinear model predictive control (NMPC). 'The presented method is based on robust multi-stage NMPC which represents the uncertainty as a scenario tree with the possibility of recourse, reducing the conservativeness of the approach. In the case of structural mismatch, the unmodeled dynamics can cause a significant difference between the model used for the predictions and the reality, which can cause violations of constraints We generate a scenario tree to account for the mismatch between the plant and the model by assuming a bound on the effect of the structural mismatch on the model Thus the proposed scheme will be robust to the structural mismatch present in the model, We demonstrate the adyantages of the proposed approach for a nonlinear continuous stirred tank reactor example.
引用
收藏
页码:1602 / 1607
页数:6
相关论文
共 17 条
[1]  
[Anonymous], 2012, RECENT ADV ALGORITHM, DOI DOI 10.1007/978-3-642-30023-3_27
[2]  
Bemporad A, 1998, IEEE DECIS CONTR P, P1384, DOI 10.1109/CDC.1998.758479
[3]  
Campo P. J., 1987, Proceedings of the 1987 American Control Conference, P1021
[4]   Optimization over state feedback policies for robust control with constraints [J].
Goulart, PJ ;
Kerrigan, EC ;
Maciejowski, JA .
AUTOMATICA, 2006, 42 (04) :523-533
[5]   Gain-scheduling trajectory control of a continuous stirred tank reactor [J].
Klatt, KU ;
Engell, S .
COMPUTERS & CHEMICAL ENGINEERING, 1998, 22 (4-5) :491-502
[6]   Worst-case formulations of model predictive control for systems with bounded parameters [J].
Lee, JH ;
Yu, ZH .
AUTOMATICA, 1997, 33 (05) :763-781
[7]  
Löfberg J, 2003, 42ND IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-6, PROCEEDINGS, P1438
[8]  
Lucia S., 2014, AUTOMATICA UNPUB
[9]  
Lucia S, 2014, 2014 EUROPEAN CONTROL CONFERENCE (ECC), P1158, DOI 10.1109/ECC.2014.6862335
[10]  