摘要
Conventional means of diagnosing and assessing the progression of osteoporosis, including radiographic absorptiometry and quantitative CT, are directly or indirectly dependent upon bone density. This is, however, not always a reliable indicator of fracture risk. Changes in the trabecular structure and bone mineral content (BMC) are thought to provide a better indication of the chance of spontaneous fractures occurring. Coherent-scatter CT (CSCT) is a technique which produces images based on the low angle (0-10 degrees) x-ray diffraction properties of tissue. Diffraction patterns from an object are acquired using first-generation CT geometry with a diagnostic x-ray image intensifier based system. These patterns are used to reconstruct a series of maps of the angle dependent coherent scatter cross section in a tomographic slice which are dependent upon the molecular structure of the scatterer. Hydroxyapatite has a very different cross section to that of soft tissue, and the CSCT method may, therefore, form the basis for a more direct measure of BMC. Our original CSCT images suffered from a "cupping" artifact, resulting in increased intensities for pixels at the periphery of the object. This artifact, which is due to self-attenuation of scattered x rays, caused a systematic error of up to 20% in cross-sections measured from a CT image. This effect has been removed by monitoring the transmitted intensity using a photodiode mounted on the primary beam stop, and normalizing the scatter intensity to that of the transmitted beam for each projection. Images reconstructed from data normalized in this way do not exhibit observable attenuation artifacts. Elimination of this artifact enables the determination of accurate quantitative measures of BMC at each pixel in a tomograph.
引用
收藏
页码:707 / 715
页数:9
相关论文
共 50 条
  • [41] QUANTITATIVE COMPUTED TOMOGRAPHY IN OSTEOPOROSIS
    Willekens, I.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2023, 35 : S195 - S195
  • [42] QUANTITATIVE COMPUTED-TOMOGRAPHY
    OVERTON, TR
    ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (05): : 629 - 629
  • [43] QUANTITATIVE INFORMATION IN COMPUTED TOMOGRAPHY
    RUTHERFORD, RA
    PULLAN, BR
    ISHERWOOD, I
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (02) : 255 - 255
  • [44] Coherent-scatter computed tomography provides detailed structural and compositional stone analysis: Early results of a prospective trial
    Wignall, Geoffrey R.
    Denstedt, John D.
    Cunningham, Ian
    JOURNAL OF UROLOGY, 2008, 179 (04): : 587 - 587
  • [45] Structural and compositional stone analysis using coherent-scatter computed tomography: Early results using a novel technique
    Wignall, Geoffrey R.
    Denstedt, John D.
    Cunningham, Ian A.
    JOURNAL OF ENDOUROLOGY, 2007, 21 : A11 - A11
  • [46] Multi-view coded aperture coherent scatter tomography
    Holmgren, Andrew D.
    Odinaka, Ikenna
    Greenberg, Joel A.
    Brady, David J.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX), 2016, 9847
  • [47] Snapshot fan beam coded aperture coherent scatter tomography
    Hassan, Mehadi
    Greenberg, Joel A.
    Odinaka, Ikenna
    Brady, David J.
    OPTICS EXPRESS, 2016, 24 (16): : 18277 - 18289
  • [48] Simulating the influence of scatter and beam hardening in dimensional computed tomography
    Lifton, J. J.
    Carmignato, S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (10)
  • [49] THE EFFECTS OF SCATTER IN X-RAY COMPUTED-TOMOGRAPHY
    JOSEPH, PM
    SPITAL, RD
    MEDICAL PHYSICS, 1982, 9 (04) : 464 - 472
  • [50] Radiation shielding implications of computed tomography scatter exposure to the floor
    Langer, SG
    Gray, JE
    HEALTH PHYSICS, 1998, 75 (02): : 193 - 196