Quantitative coherent scatter computed tomography

被引:7
|
作者
Batchelar, DL [1 ]
Westmore, MS [1 ]
Lai, H [1 ]
Cunningham, IA [1 ]
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
来源
PHYSICS OF MEDICAL IMAGING | 1998年 / 3336卷
关键词
X-ray diffraction; computed tomography; material-specific imaging; bone-mineral content (BMC);
D O I
10.1117/12.317076
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conventional means of diagnosing and assessing the progression of osteoporosis, including radiographic absorptiometry and quantitative CT, are directly or indirectly dependent upon bone density. This is, however, not always a reliable indicator of fracture risk. Changes in the trabecular structure and bone mineral content (BMC) are thought to provide a better indication of the chance of spontaneous fractures occurring. Coherent-scatter CT (CSCT) is a technique which produces images based on the low angle (0-10 degrees) x-ray diffraction properties of tissue. Diffraction patterns from an object are acquired using first-generation CT geometry with a diagnostic x-ray image intensifier based system. These patterns are used to reconstruct a series of maps of the angle dependent coherent scatter cross section in a tomographic slice which are dependent upon the molecular structure of the scatterer. Hydroxyapatite has a very different cross section to that of soft tissue, and the CSCT method may, therefore, form the basis for a more direct measure of BMC. Our original CSCT images suffered from a "cupping" artifact, resulting in increased intensities for pixels at the periphery of the object. This artifact, which is due to self-attenuation of scattered x rays, caused a systematic error of up to 20% in cross-sections measured from a CT image. This effect has been removed by monitoring the transmitted intensity using a photodiode mounted on the primary beam stop, and normalizing the scatter intensity to that of the transmitted beam for each projection. Images reconstructed from data normalized in this way do not exhibit observable attenuation artifacts. Elimination of this artifact enables the determination of accurate quantitative measures of BMC at each pixel in a tomograph.
引用
收藏
页码:707 / 715
页数:9
相关论文
共 50 条
  • [21] Comparative analysis of patient scatter to phantom scatter for computed tomography systems
    Edwards, S. M.
    Schick, D.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (3) : 883 - 888
  • [22] CORRECTION OF SCATTER IN COMPUTED-TOMOGRAPHY IMAGES
    HANGARTNER, TN
    CALCIFIED TISSUE INTERNATIONAL, 1989, 44 (02) : 146 - 146
  • [23] Comparative analysis of patient scatter to phantom scatter for computed tomography systems
    S. M. Edwards
    D. Schick
    Physical and Engineering Sciences in Medicine, 2022, 45 : 883 - 888
  • [24] Research of scatter correction on industry computed tomography
    Sun, Shao-Hua
    Gao, Wen-Huan
    Zhang, Li
    Chen, Zhi-Qiang
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 2002, 22 (05):
  • [25] Quantitative computed tomography
    Wells, P
    Davis, JR
    Kirby, BJ
    Cramond, AJ
    Fillingham, N
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1419 - 1422
  • [26] Quantitative computed tomography
    Vannier, Michael W.
    Ellingson, William A.
    Review of Progress in Quantitative Nondestructive Evaluation, 1988, 7 A : 373 - 380
  • [27] Quantitative computed tomography
    Prevrhal, S
    Genant, HK
    RADIOLOGE, 1999, 39 (03): : 194 - 202
  • [28] Quantitative computed tomography
    Adams, Judith E.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (03) : 415 - 424
  • [29] QUANTITATIVE COMPUTED TOMOGRAPHY
    WILSON, CR
    JAMES, C
    VOLZ, DJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 131 (03) : 548 - 548
  • [30] Quantitative Computed Tomography
    Lang, Thomas F.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2010, 48 (03) : 589 - +