Electrocardiographic imaging: I. Effect of torso inhomogeneities on body surface electrocardiographic potentials

被引:44
作者
Ramanathan, C
Rudy, Y
机构
[1] Case Western Reserve Univ, Cardiac Bioelect Res & Training Ctr, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Cardiac Bioelect Res & Training Ctr, Dept Physiol & Biophys, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Cardiac Bioelect Res & Training Ctr, Dept Med, Cleveland, OH 44106 USA
关键词
electrocardiography; torso inhomogeneities; mapping; body surface potentials; epicardial potentials;
D O I
10.1046/j.1540-8167.2001.00229.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Effect of Inhomogeneities on Body Surface. Introduction: Body surface potential maps (BSPMs) and conventional ECG reflect electrical sources generated by cardiac excitation and repolarization and noninvasively provide important diagnostic information about the electrical state of the heart. Because the heart is located within the torso volume conductor, body surface potentials also reflect the effects of torso inhomogeneities, which include blood, lungs, bone, muscle, fat, and fluid. It is necessary to characterize and understand these effects in order to interpret BSPM and ECG in terms of cardiac activity without "contamination" from the inhomogeneous volume conductor. Methods and Results: Actual measured epicardial and body surface potentials were obtained during normal sinus rhythm and for different pacing protocols from a Langendorff-perfused dog heart suspended in a human-shaped torso tank. Accurate geometry of the torso inhomogeneities was digitized from the Visual Human Project and appropriately introduced into a computer model of the tank setup. The geometry and electrical properties of the volume conductor could be varied. Both homogeneous and inhomogeneous torsos have major smoothing effects on BSPM, which is of very low resolution compared with its corresponding epicardial potential pattern. Relative to a homogeneous torso, the inhomogeneities have only a minor;effect on BSPM patterns. They augment potential magnitudes depending on the pattern of epicardial activation. Variations of geometry and electrical properties within the normal physiologic range have minimal effects. Conclusion: Effects of torso inhomogeneities on 12-lead ECGs are minimal, and the associated ECG changes fall within the range of normal interindividual variations.
引用
收藏
页码:229 / 240
页数:12
相关论文
共 22 条
[1]  
Brebbia CA., 1984, BOUNDARY ELEMENT TEC, DOI DOI 10.1007/978-3-642-48860-3
[3]   Noninvasive ECG imaging of electrophysiologically abnormal substrates in infarcted hearts - A model study [J].
Burnes, JE ;
Taccardi, B ;
MacLeod, RS ;
Rudy, Y .
CIRCULATION, 2000, 101 (05) :533-540
[4]   EPICARDIAL POTENTIAL MAPPING - EFFECTS OF CONDUCTING MEDIA ON ISOPOTENTIAL AND ISOCHRONE DISTRIBUTIONS [J].
GREEN, LS ;
TACCARDI, B ;
ERSHLER, PR ;
LUX, RL .
CIRCULATION, 1991, 84 (06) :2513-2521
[5]   A SIMULATION STUDY OF THE EFFECTS OF TORSO INHOMOGENEITIES ON ELECTROCARDIOGRAPHIC POTENTIALS, USING REALISTIC HEART AND TORSO MODELS [J].
GULRAJANI, RM ;
MAILLOUX, GE .
CIRCULATION RESEARCH, 1983, 52 (01) :45-56
[6]   HEART POSITION AND ORIENTATION IN FORWARD AND INVERSE ELECTROCARDIOGRAPHY [J].
HUISKAMP, GJM ;
VANOOSTEROM, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (06) :613-620
[7]  
Jackson J. D., 1975, CLASSICAL ELECTRODYN
[8]   The effects of inhomogeneities and anisotropies on electrocardiographic fields: A 3-D finite-element study [J].
Klepfer, RN ;
Johnson, CR ;
Macleod, RS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (08) :706-719
[9]   NONINVASIVE RECOVERY OF EPICARDIAL POTENTIALS IN A REALISTIC HEART-TORSO GEOMETRY - NORMAL SINUS RHYTHM [J].
MESSINGERRAPPORT, BJ ;
RUDY, Y .
CIRCULATION RESEARCH, 1990, 66 (04) :1023-1039
[10]  
Oster HS, 1997, CIRCULATION, V96, P1012