Comparison of vessel contrast measured with a scanning-beam digital x-ray system and an image intensifier/television system

被引:5
作者
Speidel, MA
Wilfley, BP
Heanue, JA
Betts, TD
Van Lysel, MS
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] NexRay Inc, Los Gatos, CA 95030 USA
[3] Univ Wisconsin, Dept Med & Med Phys, Madison, WI 53792 USA
关键词
scanning x-ray source; contrast; x-ray scatter; digital fluoroscopy; cardiac angiography;
D O I
10.1118/1.1339881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Vessel contrast was measured in the fluoroscopic images produced by a scanning-beam digital x-ray (SBDX) system and an image intensifier/television (II/TV) based system. The SBDX system electronically scans a series of pencil x-ray beams across the patient, each of which is directed at a distant small-area detector array. The reduction in detected scatter achieved with this geometry was expected to provide an increase in image contrast. Vessel contrast was evaluated from images of a phantom containing iodinated tubes. The vessels were inserted into an acrylic stack to provide a patient-mimicking scattering medium. Vessel diameter ranged from 0.3 to 3.1 mm. Images were acquired at 100 kVp with the SBDX and II/TV systems and averaged to reduce x-ray noise. The II/TV system was operated in the 6-in. image intensifier mode with an anti-scatter grid. The increase in contrast in the SBDX images, expressed as a ratio of the measured SBDX and II/TV contrasts, ranged from 1.63 to 1.79 for individual vessels. This agreed well with a prediction of the contrast improvement ratio for this experiment, based on measurements of the scatter fraction, object-plane line spread functions, and consideration of the source spectrum and detector absorption properties. The predicted contrast improvement ratio for SBDX relative to II/TV images was 1.62 to 1.77. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:232 / 240
页数:9
相关论文
共 17 条
[1]  
[Anonymous], 2010, XCOM PHOTON CROSS SE
[2]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[3]   EFFECTS OF UNDERSAMPLING ON THE PROPER INTERPRETATION OF MODULATION TRANSFER-FUNCTION, NOISE POWER SPECTRA, AND NOISE EQUIVALENT QUANTA OF DIGITAL IMAGING-SYSTEMS [J].
DOBBINS, JT .
MEDICAL PHYSICS, 1995, 22 (02) :171-181
[4]   DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES [J].
DOBBINS, JT ;
ERGUN, DL ;
RUTZ, L ;
HINSHAW, DA ;
BLUME, H ;
CLARK, DC .
MEDICAL PHYSICS, 1995, 22 (10) :1581-1593
[5]  
DOI K, 1972, PHYS MED BIOL, V17, P241, DOI 10.1088/0031-9155/17/2/010
[6]  
Firestone RB, 1996, TABLE ISOTOPES, VII
[7]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[8]   CdZnTe detector array for a Scanning-Beam Digital-X-ray system [J].
Heanue, JA ;
Pearson, DA ;
Melen, RE .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :718-725
[9]  
Hubbell J.H., 1997, Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients (version 1.03), DOI DOI 10.18434/T4D01F
[10]   COMPARISON OF SCATTER MEASUREMENT TECHNIQUES IN DIGITAL FLUOROSCOPY [J].
MAHER, KP .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (12) :1977-1983