Magnetic fields with photon beams: Monte Carlo calculations for a model magnetic field

被引:23
作者
Jette, D
机构
[1] Lawrence H Lanzl Inst Med Phys, Seattle, WA 98103 USA
[2] Rush Presbyterian St Lukes Med Ctr, Dept Med Phys, Chicago, IL 60612 USA
关键词
photon dose calculation; magnetic fields; EGS4 Monte Carlo simulations;
D O I
10.1118/1.1326447
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Strong transverse magnetic fields can produce very large dose enhancements and reductions in localized regions of a patient under irradiation by a photon beam. We have suggested a model magnetic field which can be expected to produce such large dose enhancements and reductions, and we have carried out EGS4 Monte Carlo calculations to examine this effect for a 6x6 cm(2) photon beam of energy 15, 30, or 45 MV penetrating a water phantom. Our model magnetic field has a nominal (center) strength Ed ranging between 1 and 5 T, and a maximum strength within the geometric beam which is 2.2xB(o). For all three beam energies, there is significant dose enhancement for B-0=2 T which increases greatly for B-0=3 T, but stronger magnetic fields increase the enhancement further only for the 45-MV beam. Correspondingly, there is major reduction in the dose just distal to this region of large dose enhancement, resulting from secondary electrons and positrons originating upstream which are depositing energy in the dose-enhancement region rather than continuing further into the patient. The dose peak region is fairly narrow tin depth), but the magnetic field can be shifted along the longitudinal axis to produce a flat peak region of medium width (similar to2 cm) or of large width (similar to4 cm), with rapid dose dropoffs on either side. For the 30-MV beam with B-0=3 T, we found a dose enhancement of 55% for the narrow-width configuration, 32% for the medium-width configuration, and 23% for the large-width configuration; for the 45-MV beam with B-0=3 T, the enhancements were quite similar, but for the 15-MV beam they were considerably less. For all of these 30-MV configurations, the dose reductions were similar to 30%, and they were similar to 40% for the 45-MV configurations. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00912-3].
引用
收藏
页码:2726 / 2738
页数:13
相关论文
共 13 条
[1]   THE EFFECT OF STRONG LONGITUDINAL MAGNETIC-FIELDS ON DOSE DEPOSITION FROM ELECTRON AND PHOTON BEAMS [J].
BIELAJEW, AF .
MEDICAL PHYSICS, 1993, 20 (04) :1171-1179
[2]   Correlated electrons in a million gauss [J].
Boebinger, G .
PHYSICS TODAY, 1996, 49 (06) :36-42
[3]  
CHU JCH, 2000, MED PHYS, V27, P1434
[4]   Magnetic fields with photon beams: Dose calculation using electron multiple-scattering theory [J].
Jette, D .
MEDICAL PHYSICS, 2000, 27 (08) :1705-1716
[5]   PHOTON-BEAM CHARACTERISTICS ON THE MM50 RACETRACK MICROTRON AND A NEW APPROACH FOR BEAM QUALITY DETERMINATION [J].
KARLSSON, M ;
NYSTROM, H ;
SVENSSON, H .
MEDICAL PHYSICS, 1993, 20 (01) :143-149
[6]  
LI XA, 2000, MED PHYS, V27, P1447
[7]  
MA CM, 1997, IMPLEMENTATION MAGNE
[8]   A CONVOLUTION METHOD OF CALCULATING DOSE FOR 15-MV X-RAYS [J].
MACKIE, TR ;
SCRIMGER, JW ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1985, 12 (02) :188-196
[9]   Electron beam therapy with transverse magnetic fields [J].
Nardi, E ;
Barnea, G .
MEDICAL PHYSICS, 1999, 26 (06) :967-973
[10]  
NELSON WR, 1985, 265 STANF U