Retrofitting damaged unreinforced masonry using external shear strengthening techniques

被引:32
作者
Mustafaraj, Enea [1 ]
Yardim, Yavuz [2 ]
机构
[1] Epoka Univ, Dept Civil Engn, Km12, Vore 1039, Albania
[2] Univ Edinburgh, Sch Engn, Edinburgh EH9 3FB, Midlothian, Scotland
关键词
Diagonal compression test; Retrofitting; Shear strengthening; Ferrocement jacketing; Damaged masonry; DIAGONAL TENSION STRENGTH; BRICK MASONRY; INPLANE BEHAVIOR; BONDED FRP; WALLS; CONCRETE; PANELS; REINFORCEMENT; FERROCEMENT; COLUMNS;
D O I
10.1016/j.jobe.2019.100913
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The in-plane shear behavior of unreinforced masonry panels retrofitted with three different techniques was investigated, and in particular the effectiveness of reinforcing methods to restrain the diagonal cracking failure mode was studied. Fifteen standard sized panels of 1.2 x 1.2 x 0.25 m were subjected to diagonal compression testing and then repaired using polypropylene fiber reinforced mortar, ferrocement jacketing, or carbon fiber reinforced polymer (CFRP) wraps applied externally on both sides. The panels were made of two different types of mortar; type N representing modern masonry buildings and type O mortars for older buildings of the 1950s and earlier. Several parameters such as mode of failure, shear stress-strain behavior, shear strength, shear modulus, elastic modulus, and ultimate drift were determined. At the end of 30 diagonal compression tests, plain panels exhibited sudden brittle failure mainly characterized by step-like cracks along the diagonal, whereas retrofitted panels had a more ductile behavior, with an increment of shear strength by 161-454% and of ultimate drift by 863-1486%.
引用
收藏
页数:11
相关论文
共 47 条
[1]  
Ahmed T., 1994, FERROCEMENT
[2]   Shear strength of brick masonry walls assembled with different types of mortar [J].
Alecci, Valerio ;
Fagone, Mario ;
Rotunno, Tommaso ;
De Stefano, Mario .
CONSTRUCTION AND BUILDING MATERIALS, 2013, 40 :1038-1045
[3]  
[Anonymous], 1998, P 4 INT S COMPUTER M
[4]  
[Anonymous], E51907 ASTM INT
[5]  
[Anonymous], 2021, ASTM C67/C67M-21, DOI [10.1520/C0067_C0067M-21, DOI 10.1520/C0067_C0067M-21]
[6]  
ASTM, 2003, C109C109M16A ASTM IN
[7]  
ASTM, 2004, C131404 ASTM INT
[8]   Shear behavior of unreinforced and reinforced masonry panels subjected to in situ diagonal compression tests [J].
Borri, A. ;
Castori, G. ;
Corradi, M. ;
Speranzini, E. .
CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (12) :4403-4414
[9]   Determination of Shear Strength of Masonry Panels Through Different Tests [J].
Borri, Antonio ;
Castori, Giulio ;
Corradi, Marco .
INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2015, 9 (08) :913-927
[10]   Shear behaviour of masonry walls strengthened by external bonded FRP and TRC [J].
Bui, Thi-Loan ;
Larbi, A. Si ;
Reboul, N. ;
Ferrier, E. .
COMPOSITE STRUCTURES, 2015, 132 :923-932