摘要
The surface of an electrochemical glassy carbon electrode was modified with a layer of double-stranded DNA (dsDNA) or with double-stranded DNA conditioned in single-stranded DNA (ssDNA) and was used to investigate mitoxantrone-DNA interactions. Differential pulse and square wave voltammetry were applied to develop an electroanalytical procedure for the determination of mitoxantrone and evaluate its interaction with dsDNA or ssDNA immobilized on the electrode surface. The results demonstrate that MTX interaction with DNA is not specific to either guanine or adenine bases. The kinetics of the mitoxantrone-DNA interaction is slow and damage to DNA was followed with time. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:861 / 867
页数:7
相关论文
共 50 条
  • [11] The polarographic and voltammetric behaviour of mitoxantrone and analytical applications
    Yang, P
    Wang, HF
    Zhou, GR
    Fan, HZ
    Pan, JH
    ANALYTICAL LETTERS, 1996, 29 (01) : 89 - 96
  • [12] A ratiometric electrochemical DNA-biosensor for detection of miR-141
    Khodadoust, Ali
    Nasirizadeh, Navid
    Taheri, Ramezan Ali
    Dehghani, Mohammad
    Ghanei, Mostafa
    Bagheri, Hasan
    MICROCHIMICA ACTA, 2022, 189 (06)
  • [13] COMP 340-Molecular dynamics simulations of a DNA-biosensor
    Le Bouch, Nolwenn
    Brisson, Josee
    Leclerc, Mario
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [14] Electrochemical detection of the toxic dinoflagellate Alexandrium ostenfeldii with a DNA-biosensor
    Metfies, K
    Huljic, S
    Lange, M
    Medlin, LK
    BIOSENSORS & BIOELECTRONICS, 2005, 20 (07): : 1349 - 1357
  • [15] A ratiometric electrochemical DNA-biosensor for detection of miR-141
    Ali Khodadoust
    Navid Nasirizadeh
    Ramezan Ali Taheri
    Mohammad Dehghani
    Mostafa Ghanei
    Hasan Bagheri
    Microchimica Acta, 2022, 189
  • [16] A novel sensitive DNA-biosensor for detection of a carcinogen, Sudan II, using electrochemically treated pencil graphite electrode by voltammetric methods
    Ensafi, Ali A.
    Rezaei, Behzad
    Amini, Maryam
    Heydari-Bafrooei, Esmaeil
    TALANTA, 2012, 88 : 244 - 251
  • [17] Effect of concentration of ligands on DNA-biosensor average output signal and dispersion
    Arakelyan, Valeri B.
    Parsadanyan, Marine A.
    Vardevanyan, Poghos O.
    JOURNAL OF BIOMOLECULAR STRUCTURE & DYNAMICS, 2019, 37 : 79 - 79
  • [18] A wireless magnetoelastic DNA-biosensor amplified by AuNPs for the detection of a common mutated DNA causing β-thalassaemia
    Guo, Xing
    Wang, Jingzhe
    Zhao, Yajing
    Liu, Rong
    Zhang, Qiang
    Yuan, Zhongyun
    Sang, Shengbo
    BIOCHEMICAL ENGINEERING JOURNAL, 2020, 156
  • [19] Detection of the damage caused to DNA by a thiophene-S-oxide using an electrochemical DNA-biosensor
    Brett, AMO
    da Silva, LA
    Fujii, H
    Mataka, S
    Thiemann, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 549 (SUPPL.) : 91 - 99
  • [20] Voltammetric detection of damage to DNA by arsenic compounds at a DNA biosensor
    Labuda, J
    Bubnicova, K
    Kovalova, L
    Vanickova, M
    Mattusch, J
    Wennrich, R
    SENSORS, 2005, 5 (6-10): : 411 - 423