Aerodynamic analysis and CFD simulation of several cellulose evaporative cooling pads used in Mediterranean greenhouses

被引:68
作者
Franco-Salas, Antonio [2 ]
Valera, D. L. [1 ]
Pena, A. [1 ]
Perez, A. M. [2 ]
机构
[1] Univ Almeria, Ctra Sacramento S-N, Almeria 04120, Spain
[2] Univ Seville, ETSIA, Seville 41013, Spain
关键词
Greenhouse; Aerodynamic analysis; CFD; Evaporative cooling; Fan and pad; Pressure drop; INSECT-PROOF SCREENS; AIR-FLOW; NATURAL VENTILATION; TEMPERATURE; PERFORMANCE; SYSTEM; HUMIDITY; WATER;
D O I
10.1016/j.compag.2011.01.019
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The present work makes an aerodynamic analysis and computational fluid dynamics (CFD) simulation of the four commercial models of corrugated cellulose evaporative cooling pads that are most widely used in Mediterranean greenhouses. The geometric characteristics of the pads have been determined as well as the volume of water they retain at different flows of water, thus obtaining the mean thickness of the sheet of water which runs down them and their porosity. By means of low velocity wind tunnel experiments, the pressure drop produced by the pads has been recorded at different wind speeds and water flows. In this way it has been possible to obtain the relationship of the permeability and the inertial factor with pad porosity using a cubic type equation. Finally, a CFD simulation with a 3D model has been carried out for both dry pads (Q(w) = 0 l s(-1) m(-2)) and wet ones (Q(w) = 0.256 l s(-1) m(-2)), finding good correlation between the simulated and experimental pressure drop, with maximum differences of 9.08% for dry pads and 15.53% for wet ones at an airspeed of 3 m s(-1). (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 230
页数:13
相关论文
共 53 条
[11]   Ventilation of small multispan greenhouse in relation to the window openings calculated with CFD [J].
Campen, J. B. .
Proceedings of the IIIrd International Symposium on Models for Plant Growth, Environmental Control and Farm Management in Protected Cultivation, 2006, (718) :351-356
[12]  
Castilla N., 2005, Chronica Horticulturae, V45, P15
[13]   Performance characteristics of a pad evaporative cooling system in a broiler house in a Mediterranean climate [J].
Dagtekin, Metin ;
Karaca, Cengiz ;
Yildiz, Yilmaz .
BIOSYSTEMS ENGINEERING, 2009, 103 (01) :100-104
[14]   Flow reduction of synthetic screens obtained with both a water and airflow apparatus [J].
Dierickx, W .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1998, 71 (01) :67-73
[15]   Thermal and hydraulic performance of a modified two-stage evaporative cooler [J].
ElDessouky, HTA ;
AlHaddad, AA .
RENEWABLE ENERGY, 1996, 7 (02) :165-176
[16]   Experimental and analytical evaluation of flow in a square-to-square wind tunnel contraction [J].
Fang, FM ;
Chen, JC ;
Hong, YT .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2001, 89 (3-4) :247-262
[17]   Dependence of greenhouse tunnel ventilation on wind direction and crop height [J].
Fatnassi, H. ;
Leyronas, C. ;
Boulard, T. ;
Bardin, M. ;
Nicot, P. .
BIOSYSTEMS ENGINEERING, 2009, 103 (03) :338-343
[18]   Flow Characteristics and Temperature Patterns in a Fan Ventilated Greenhouse [J].
Fidaros, D. ;
Baxevanou, C. ;
Bartzanas, T. ;
Kittas, C. .
PROCEEDINGS OF THE INTERNATIONAL WORKSHOP ON GREENHOUSE ENVIRONMENTAL CONTROL AND CROP PRODUCTION IN SEMI-ARID REGIONS, 2008, (797) :123-+
[19]   On the non-linear behavior of a laminar single-phase flow through two and three-dimensional porous media [J].
Fourar, M ;
Radilla, G ;
Lenormand, R ;
Moyne, C .
ADVANCES IN WATER RESOURCES, 2004, 27 (06) :669-677
[20]  
Franco-Salas A, 2010, T ASABE, V53, P565