Comparison of the surface detail reproduction of flexible die material systems

被引:10
作者
Gerrow, JD [1 ]
Price, RB [1 ]
机构
[1] Dalhousie Univ, Fac Dent, Dept Clin Dent Sci, Halifax, NS B3H 3J5, Canada
关键词
D O I
10.1016/S0022-3913(98)70016-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Flexible die materials have been introduced to facilitate the fabrication of indirect provisional or definitive restorations in 1 appointment. Purpose. This study compared the surface detail reproduction of 7 potential flexible die materials when used in combination with 7 elastomeric impression materials. Methods. Surface detail reproduction of 17 impression material/flexible die material systems was compared with a control system containing an elastomeric impression material and a Type IV dental stone. Test dies of each system were prepared in a random order with the American Dental Association apparatus for testing detail reproduction, compatibility, and dimensional stability. Results. One flexible die system had better surface detail reproduction than the control stone die, other systems had similar or worse reproduction. Surface detail reproduction was adversely affected when a separator was required between the impression and flexible die material. Conclusions. Impregum F die material with Extrude Light impression material produced better surface detail reproduction than the control dies. Impregum F impressions were incompatible with Blu-Mousse, Impregum F, or Imprint die materials. Polyvinyl siloxane impressions were incompatible with polyvinyl siloxane dies unless a separator was used. When a separator was used, the surface detail reproduction was not as good as the control die system or the Extrude Light impression material/Impregum F die material combination.
引用
收藏
页码:485 / 489
页数:5
相关论文
共 14 条
[1]  
American Dental Association, 1977, J AM DENT ASSOC, V94, P733
[3]   MICROLEAKAGE STUDIES COMPARING A ONE-VISIT INDIRECT COMPOSITE INLAY SYSTEM AND A DIRECT COMPOSITE RESTORATIVE TECHNIQUE [J].
CASSIN, AM ;
PEARSON, GJ .
JOURNAL OF ORAL REHABILITATION, 1992, 19 (03) :265-270
[4]  
FLEISS JL, 1981, STATISTICAL METHODS, P150
[5]   A COMPARISON OF THE COMPATIBILITY OF ELASTOMERIC IMPRESSION MATERIALS, TYPE-IV DENTAL STONES, AND LIQUID-MEDIA [J].
GERROW, JD ;
SCHNEIDER, RL .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (03) :292-298
[6]  
Moulding M B, 1994, Int J Prosthodont, V7, P554
[7]  
Nash R W, 1990, Dent Today, V9, P26
[8]  
PRISMA APH, INLAY SYSTEM
[9]  
Reid J S, 1993, Am J Dent, V6, P81
[10]   FLEXIBLE CASTS USED IN MAKING INDIRECT INTERIM RESTORATIONS [J].
ROBERTS, DB .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (02) :372-374