Effect of Signal Strength on Reproducibility of Peripapillary Retinal Nerve Fiber Layer Thickness Measurement and Its Classification by Time-Domain Optical Coherence Tomography

被引:6
作者
Lee, Eun Suk [2 ]
Kim, Hyunjoong [3 ]
Kim, Joon Mo [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Ophthalmol, Seoul 100746, South Korea
[2] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul, South Korea
[3] Yonsei Univ, Dept Appl Stat, Seoul 120749, South Korea
关键词
agreement; classification; optical coherence tomography; reproducibility; retinal nerve fiber layer; STRATUS OCT; GLAUCOMATOUS EYES; VARIABILITY;
D O I
10.1007/s10384-010-0850-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the effect of signal strength (SS) on reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness measurement (measurement agreement) and its color-coded classification (classification agreement) by time-domain optical coherence tomography (OCT). Methods: Two consecutive Stratus OCT scans with the Fast RNFL protocol were performed in 658 participants. Intraclass correlations and the linear-weighted kappa coefficient were calculated as indicators of RNFL measurement and classification agreement in participants grouped according to the difference in SS between consecutive OCT scans (interscan SS difference). Results: Groups with a larger interscan SS difference (= 2) had lower measurement agreement than those with a smaller interscan SS difference (0 or 1) for the temporal quadrant and total average RNFL. Classification agreement for the nasal quadrant was lower in the groups with a larger interscan SS difference (= 2) than in those with a smaller interscan SS difference. The tendency of SS to affect classification and measurement agreement remained similar in the group with thinner RNFL thickness (<= 85 mu m), but not in the group with thicker RNFL. Conclusions: Careful attention should be paid when comparing two or more OCT scans for RNFL thickness measurement or its color-coded classification as the agreement may be sensitive to SS differences. Jpn J Ophthalmol 2010;54:414-422 (C) Japanese Ophthalmological Society 2010
引用
收藏
页码:414 / 422
页数:9
相关论文
共 14 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R, DOI DOI 10.1201/9780429258589
[2]  
Antón A, 2009, CLIN OPHTHALMOL, V3, P139
[3]   Inter-device Variability of the Stratus Optical Coherence Tomography [J].
Barkana, Yaniv ;
Burgansky-Eliash, Zvia ;
Gerber, Yariv ;
Melamed, Shlomo ;
Neudorfer, Meira ;
Avni, Isaac ;
Bartov, Elisha ;
Morad, Yair .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (02) :260-266
[4]   Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes [J].
Budenz, DL ;
Chang, RT ;
Huang, XR ;
Knighton, RW ;
Tielsch, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2440-2443
[5]   Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes [J].
Budenz, Donald L. ;
Fredette, Marie-Josee ;
Feuer, William J. ;
Anderson, Douglas R. .
OPHTHALMOLOGY, 2008, 115 (04) :661-666
[6]   Determinants of normal retinal nerve fiber layer thickness measured by stratus OCT [J].
Budenz, Donald L. ;
Anderson, Douglas R. ;
Varma, Rohit ;
Schuman, Joel ;
Cantor, Louis ;
Savell, Jonathan ;
Greenfeld, David S. ;
Patella, Vincent Michael ;
Quigley, Harry A. ;
Tielsch, James .
OPHTHALMOLOGY, 2007, 114 (06) :1046-1052
[7]   Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography [J].
Cheung, Carol Yim Lui ;
Leung, Christopher Kai Shun ;
Lin, Dusheung ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2008, 115 (08) :1347-1351
[8]  
Knighton RW, 2000, J GLAUCOMA, V9, P56
[9]   Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography A Variability and Diagnostic Performance Study [J].
Leung, Christopher Kai-shun ;
Cheung, Carol Yim-lui ;
Weinreb, Robert N. ;
Qiu, Quanliang ;
Liu, Shu ;
Li, Haitao ;
Xu, Guihua ;
Fan, Ning ;
Huang, Lina ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2009, 116 (07) :1257-1263
[10]  
Nunnally, 1978, Psychometric theory, V2nd ed.