Practical aspects of ultrahigh pressure capillary liquid chromatography

被引:154
作者
Wu, NJ
Lippert, JA
Lee, ML [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Weber State Univ, Dept Chem, Ogden, UT 84408 USA
关键词
capillary columns; sample introduction; column packing; ultrahigh pressure;
D O I
10.1016/S0021-9673(00)01188-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel pressure-balanced injection valve was evaluated for use with ultrahigh pressure liquid chromatography (UHPLC) at pressures up to 120 MPa (1200 bar). Fused-silica capillaries (30-33 cmX100 mum I.D.) packed with nonporous 1.5 mum isohexylsilane-modified (C-6) silica particles were employed to study maximum pressure, injection reproducibility, injection time, and sample amount consumed for an injection. The new valve was more reproducible, convenient, and required much less sample than previously used injection systems. The effect of column diameter on efficiency and sensitivity was studied. The 100 mum I.D. columns demonstrated approximately 40% lower efficiency but 10-fold higher sensitivity than the 29 mum LD. columns. Columns packed with nonporous C-6 particles produced higher efficiencies than columns packed with a 1.5 mum porous octadecylsilane-modified (C-18) material. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 25 条
[1]   RADIAL DISPERSION FROM COMMERCIAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS INVESTIGATED WITH MICROVOLTAMMETRIC ELECTRODES [J].
BAUR, JE ;
KRISTENSEN, EW ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2334-2338
[2]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[3]   EFFECT OF COLUMN DIAMETER ON PLATE HEIGHT IN HIGH-SPEED LIQUID-CHROMATOGRAPHY USING PELLICULAR AND PERFUSED PARTICLES IN PACKED CAPILLARIES [J].
COLE, LJ ;
SCHULTZ, NM ;
KENNEDY, RT .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (05) :433-439
[4]   PACKING TECHNOLOGY, COLUMN BED STRUCTURE AND CHROMATOGRAPHIC PERFORMANCE OF 1-2-MU-M NON-POROUS SILICAS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GIESCHE, H ;
UNGER, KK ;
ESSER, U ;
ERAY, B ;
TRUDINGER, U ;
KINKEL, JN .
JOURNAL OF CHROMATOGRAPHY, 1989, 465 (01) :39-57
[5]  
Gluckman J. C., 1985, J CHROMATOGR LIBR, V30, P57
[6]  
Guiochon G., 1984, MICROCOLUMN HIGH PER
[7]   ULTIMATE LIMITS IN HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
HALASZ, I ;
ENDELE, R ;
ASSHAUER, J .
JOURNAL OF CHROMATOGRAPHY, 1975, 112 (OCT29) :37-60
[8]   Preparation and evaluation of slurry-packed liquid chromatography microcolumns with inner diameters from 12 to 33 mu m [J].
Hsieh, SC ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1212-1217
[9]   LIQUID-CHROMATOGRAPHY IN OPEN-TUBULAR COLUMNS - THEORY OF COLUMN OPTIMIZATION WITH LIMITED PRESSURE AND ANALYSIS TIME, AND FABRICATION OF CHEMICALLY BONDED REVERSED-PHASE COLUMNS ON ETCHED BOROSILICATE GLASS-CAPILLARIES [J].
JORGENSON, JW ;
GUTHRIE, EJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :335-348
[10]   SEPARATION EFFICIENCY OF SLURRY-PACKED LIQUID-CHROMATOGRAPHY MICROCOLUMNS WITH VERY SMALL INNER DIAMETERS [J].
KARLSSON, KE ;
NOVOTNY, M .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1662-1665