Convergent-divergent micromixer coupled with pulsatile flow

被引:84
作者
Afzal, Arshad [1 ]
Kim, Kwang-Yong [1 ]
机构
[1] Inha Univ, Dept Mech Engn, Inchon 402751, South Korea
基金
新加坡国家研究基金会;
关键词
Pulsatile flow; Convergent-divergent micromixer; Mixing index; Strouhal number; Navier-Stokes equations; ENHANCEMENT; MIXER;
D O I
10.1016/j.snb.2015.01.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An efficient mixing system for a microfluidic platform that uses periodic sinusoidal characteristics in space and time is proposed in this work. A convergent-divergent channel with sinusoidal walls (space-periodic) represented the most effective coupling with pulsatile (time-periodic) flow among the five tested geometries. The effects of sinusoidal pulsing on mixing performance in the convergent-divergent microchannel were examined using unsteady Navier-Stokes equations. The mixing performance was analyzed using the Reynolds and Strouhal numbers, and the ratio of pulsing amplitude to steady flow velocity. The micromixer shows interesting mixing behaviors with these parameters in terms of instantaneous mixing patterns as well as overall mixing performance. The micromixer with pulsing inputs achieved mixing index, 0.92 within two periods of the sinusoidal walls. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:198 / 205
页数:8
相关论文
共 23 条
[1]   Mixing Performance of Passive Micromixer with Sinusoidal Channel Walls [J].
Afzal, Arshad ;
Kim, Kwang-Yong .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2013, 46 (03) :230-238
[2]  
[Anonymous], 2006, CFX 12 1 SOLV THEOR
[3]   A minute magneto hydro dynamic (MHD) mixer [J].
Bau, HH ;
Zhong, JH ;
Yi, MQ .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (2-3) :207-215
[4]  
Bird R. B., 1960, TRANSPORT PHENOMENON, V2nd
[5]   An ultrashort mixing length micromixer: The shear superposition micromixer [J].
Bottausci, Frederic ;
Cardonne, Caroline ;
Meinhart, Carl ;
Mezic, Igor .
LAB ON A CHIP, 2007, 7 (03) :396-398
[6]   Electro-hydrodynamic micro-fluidic mixer [J].
El Moctar, AO ;
Aubry, N ;
Batton, J .
LAB ON A CHIP, 2003, 3 (04) :273-280
[7]   Parameters influencing pulsed flow mixing in microchannels [J].
Glasgow, I ;
Lieber, S ;
Aubry, N .
ANALYTICAL CHEMISTRY, 2004, 76 (16) :4825-4832
[8]   Enhancement of microfluidic mixing using time pulsing [J].
Glasgow, I ;
Aubry, N .
LAB ON A CHIP, 2003, 3 (02) :114-120
[9]  
Glasgow I., 2003, 7 INT C MIN CHEM BIO
[10]  
Harrison DJ, 1996, SENSOR ACTUAT B-CHEM, V33, P105, DOI 10.1016/0925-4005(96)01932-6