Influence of different film cooling arrangements on endwall cooling

被引:48
作者
Li, Xueying [1 ]
Ren, Jing [1 ]
Jiang, Hongde [1 ]
机构
[1] Tsinghua Univ, Dept Thermal Engn, Beijing 100084, Peoples R China
基金
中国博士后科学基金;
关键词
Film cooling arrangement; Endwall; Adiabatic film cooling effectiveness; HEAT-TRANSFER;
D O I
10.1016/j.ijheatmasstransfer.2016.06.047
中图分类号
O414.1 [热力学];
学科分类号
摘要
The complex large scale coherent vortex systems which originate and develop through the endwall passage have strong interaction with the film cooling flows near the endwall. Two full coverage film cooling arrangements on a typical flat vane endwall were investigated experimentally. The influence of coolant mass flow rate and density ratio on each configuration was studied. Detailed measurements of adiabatic film cooling effectiveness distribution were conducted using PSP technique. The characteristics of different film cooling arrangements were analyzed. As the coolant mass flow rate rises, the film cooling coverage becomes better for both configurations. The influence of density ratio on film cooling distribution is quite complex. The results indicate that the configuration with iso-pressure line distributed film cooling has a more uniform distribution of film cooling effectiveness while the configuration with axial distributed film cooling has a better coverage mainly downstream of the passage. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:348 / 359
页数:12
相关论文
共 30 条
[1]  
Andrei L., 2014, GT201426894 ASME
[2]  
[Anonymous], 2013, ASME Paper No. GT2013
[3]  
Barigozzi G., 2005, ASME Paper No. GT2005-68544
[4]   EXPERIMENTAL-DETERMINATION OF STATOR ENDWALL HEAT-TRANSFER [J].
BOYLE, RJ ;
RUSSELL, LM .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1990, 112 (03) :547-558
[5]  
Burd S.W., 2000, 2000GT200 ASME 2
[6]   Comparison between PSP and TLC steady state techniques for adiabatic effectiveness measurement on a multiperforated plate [J].
Caciolli, G. ;
Facchini, B. ;
Picchi, A. ;
Tarchi, L. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 48 :122-133
[7]  
Correa SM, 1998, TWENTY-SEVENTH SYMPOSIUM (INTERNATIONAL) ON COMBUSTION, VOLS 1 AND 2, P1793
[8]   The design of an improved endwall film-cooling configuration [J].
Friedrichs, S ;
Hodson, HP ;
Dawes, WN .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1999, 121 (04) :772-780
[9]   Aerodynamic aspects of endwall film-cooling [J].
Friedrichs, S ;
Hodson, HP ;
Dawes, WN .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1997, 119 (04) :786-793
[10]   Distribution of film-cooling effectiveness on a turbine endwall measured using the ammonia and diazo technique [J].
Friedrichs, S ;
Hodson, HP ;
Dawes, WN .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1996, 118 (04) :613-621