Evaluation of an efficient GPU implementation of digitally reconstructed radiographs in 3D/2D image registration

被引:1
作者
Zhang, Chong [1 ]
Villa-Uriol, Maria-Cruz [1 ]
Frangi, Alejandro F. [1 ]
机构
[1] Univ Pompeu Fabra, Ctr Computat Imaging & Simulat Technol Biomed, Barcelona, Spain
来源
MEDICAL IMAGING 2010: IMAGE PROCESSING | 2010年 / 7623卷
关键词
Digitally reconstructed radiographs; GPU computing; Image registration; VOLUME RENDERING METHOD; CEREBRAL ANEURYSMS; ATTENUATION FIELDS;
D O I
10.1117/12.843909
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Intensity-based three-dimensional to two-dimensional (3D/2D) X-ray image registration algorithms usually require generating digitally reconstructed radiographs (DRRs) in every iteration during their optimization phase. Thus a large part of the computation time of such registration algorithms is spent in computing these DRRs. In a 3D-to-multiple-2D image registration framework where a sequence of DRRs is calculated, not only the computation but also the memory cost is high. We present an efficient DRR generation method to reduce both costs on a graphical processing units (GPU) implementation. The method relies on integrating a precomputation stage and a narrow-band region-of-interest calculation into the DRR generation. We have demonstrated its benefits on a previously proposed non-rigid 4D-to-multiple-2D image registration framework to estimate cerebral aneurysm wall motion. The two tested algorithms initially required several hours of highly intensive computation that involves generating a large number of DRRs in every iteration. In this paper, results on datasets of digital and physical pulsating cerebral aneurysm phantoms showed a speedup factor of around 50x in the generation of DRRs. In further image registration based wall motion estimation experiments using our implementation, we could obtain estimation results through the whole cardiac cycle within 5 minutes without degrading the overall performance.
引用
收藏
页数:8
相关论文
共 21 条
  • [1] [Anonymous], 2008, Advances in automatic differentiation, DOI [DOI 10.1007/978-3-540-68942-3_23, DOI 10.1007/978-3-540-68942-323]
  • [2] [Anonymous], TR93027 U N CAR CHAP
  • [3] Wobbled splatting - a fast perspective volume rendering method for simulation of x-ray images from CT
    Birkfellner, W
    Seemann, R
    Figl, M
    Hummel, J
    Ede, C
    Homolka, P
    Yang, XH
    Niederer, P
    Bergmann, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (09) : N73 - N84
  • [4] Medical progress: Cerebral aneurysms
    Brisman, Jonathan L.
    Song, Joon K.
    Newell, David W.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (09) : 928 - 939
  • [5] Accelerated ray tracing for radiotherapy dose calculations on a GPU
    de Greef, M.
    Crezee, J.
    van Eijk, J. C.
    Pool, R.
    Bel, A.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4095 - 4102
  • [6] Stream processors: a new platform for Monte Carlo calculations
    Despres, Philippe
    Rinkel, Jean
    Hasegawa, Bruce H.
    Prevrhal, Sven
    [J]. INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [7] DORGHAM O, 2009, MED IMAGE UNDERSTAND, P239
  • [8] DORGHAM O, 2008, MED IMAGE UNDERSTAND, P261
  • [9] IEEE, 2009, " IEEE Std 1547.2-2008, DOI [DOI 10.1109/IEEESTD.2008.4610935, 10.1109/IEEESTD.2008.4610935, 10.1109/IEEESTD.2017.8091139, DOI 10.1109/IEEESTD.2019.8766229, 10.1109/IEEESTD.2008.4816078, DOI 10.1109/IEEESTD.2008.4816078]
  • [10] Visualizing the dynamics of cerebral aneurysms with four-dimensional computed tomographic angiography
    Ishida, F
    Ogawa, H
    Simizu, T
    Kojima, T
    Taki, W
    [J]. NEUROSURGERY, 2005, 57 (03) : 460 - 470