Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement

被引:125
作者
Matziolis, Georg [1 ]
Adam, Joern [1 ]
Perka, Carsten [1 ]
机构
[1] Charite, Dept Orthopaed, D-10117 Berlin, Germany
关键词
Total knee arthroplasty; Malalignment; Outcome; Varus; COMPUTER NAVIGATION; CORONAL ALIGNMENT; LOWER-LIMB; ARTHROPLASTY; PROSTHESIS; MECHANISMS; FAILURE;
D O I
10.1007/s00402-010-1064-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Varus malalignment after total knee replacement is mentioned to be a major risk factor for postoperative pain and functional impairments. This wide spread opinion is based on the historical data derived from implantations performed in the late 1970s and early 1980s. We tested the hypothesis whether significant varus malalignment leads to minor functional results and early loosening using modern implants and operating techniques. Two hundred and eighteen knee joints (184 patients) having been replaced with a PFC Sigma or Natural Knee II with a minimum follow-up of 5 years were included in this case control study. From the 30 most varus malaligned knees (30 patients) 25 patients were available for clinical and radiographical examination (group A) and were compared with a control group without significant varus malalignment that was matched for sex, age and implant (group B). The Knee Society Score (KSS), the WOMAC and the SF36 were determined. No implant showed radiological signs of loosening or had been revised. The deviation from the mechanical axis was 6.3A degrees [3.9A degrees-10.7A degrees varus] in group A and 0A degrees [2.6A degrees valgus to 2.1A degrees varus] in group B (P < 0.001). The KSS was 158 [99-199] points in group A and 142 [78-198] points in group B (n.s.). The WOMAC did not reveal any significant differences between the groups either (group A 22 +/- A 27 points, group B 21 +/- A 21 points). Likewise in the SF36, neither in the sum nor in the individual scores was a significant difference found between groups A (56 +/- A 24 [8-90] points) and B (56 +/- A 18 [26-86] points). The present data do not support the assumption that there is a correlation between varus malalignment and a bad medium-term radiological and clinical outcome after total knee arthroplasty. This questions the indication for revision of painful and varus malaligned prostheses, since an improvement of the clinical outcome is not to be expected.
引用
收藏
页码:1487 / 1491
页数:5
相关论文
共 25 条
[1]  
Akagi M, 1999, CLIN ORTHOP RELAT R, P155
[2]   Computer assisted navigation in total knee arthroplasty - Comparison with conventional methods [J].
Anderson, KC ;
Buehler, KC ;
Markel, DC .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :132-138
[3]  
[Anonymous], 2008, SWEDISH KNEE ARTHROP
[4]  
BARGREN JH, 1983, CLIN ORTHOP RELAT R, P178
[5]  
Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
[6]   Tibial component failure mechanisms in total knee arthroplasty [J].
Berend, ME ;
Ritter, MA ;
Meding, JB ;
Faris, PM ;
Keating, EM ;
Redelman, R ;
Faris, GW ;
Davis, KE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :26-34
[7]   Computer navigation versus standard instrumentation for TKA - A single-surgeon experience [J].
Bolognesi, M ;
Hofmann, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :162-169
[8]   A QUANTITATIVE APPROACH TO RADIOGRAPHY OF THE LOWER-LIMB - PRINCIPLES AND APPLICATIONS [J].
COOKE, TDV ;
SCUDAMORE, RA ;
BRYANT, JT ;
SORBIE, C ;
SIU, D ;
FISHER, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :715-720
[9]   Alignments and clinical results in conventional and navigated total knee arthroplasty [J].
Ensini, A. ;
Catani, F. ;
Leardini, A. ;
Romagnoli, M. ;
Giannini, S. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (457) :156-162
[10]   The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty - The posteromedial hot spot [J].
Green, GV ;
Berend, KR ;
Berend, ME ;
Glisson, RR ;
Vail, TP .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1033-1039