Immunoassay for Quantifying Squamous Cell Carcinoma Antigen in Serum

被引:38
作者
Erickson, J. Alan [1 ,2 ]
Lu, Jun [2 ]
Smith, Jeffery J. [1 ]
Bornhorst, Joshua A. [3 ]
Grenache, David G. [2 ,3 ]
Ashwood, Edward R. [2 ,3 ]
机构
[1] ARUP Labs, Salt Lake City, UT 84108 USA
[2] ARUP Inst Clin & Expt Pathol, Salt Lake City, UT USA
[3] Univ Utah, Hlth Sci Ctr, Dept Pathol, Salt Lake City, UT 84132 USA
关键词
SCC ANTIGEN; MONOCLONAL-ANTIBODIES; BLOCKING REAGENTS; CERVICAL-CANCER; INTERFERENCES; MANAGEMENT; OVARIAN; BENIGN;
D O I
10.1373/clinchem.2010.143156
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Although the benefits of quantifying serum squamous cell carcinoma antigen (SCCa) have been reported, SCCa reagents were no longer available in the US by the late 1990s. Because SCCa quantification still has demonstrated clinical utility, we developed and validated a microtiter plate-based ELISA for measuring SCCa in serum. METHODS: We coated microtiter strips overnight with capture anti-SCCa monoclonal antibody, washed the wells, added blocking buffer, and lyophilized the strips. For detection, we used a biotinylated anti-SCCa detection antibody, streptavidin/horseradish peroxidase conjugate, and tetramethylbenzidine/ H(2)O(2) substrate. Anovel blocking reagent against human antimouse antibodies (HAMA) was evaluated. A reference interval was established with sera from healthy individuals and was confirmed in smokers. RESULTS: The assay was linear to 40 mu g/L SCCa (slope, 1.00; y intercept, 0.695; R(2), 0.996) with a detection limit of 0.3 mu g/L. The intraassay imprecision results [ mean (CV)] were 2.5 mu g/L (3.4%), 18.0 mu g/L (3.0%), and 30.7 mu g/L (2.4%); interassay imprecision results were 2.0 mu g/L (9.9%), 20.0 mu g/L (7.6%), and 36.3 mu g/L (3.5%). A correlation analysis against an established automated assay generated a slope of 0.976 and a y intercept of -0.193 mu g/L (r(2) = 0.916). An upper reference limit of 2.1 mu g/L SCCa was established at 95% confidence level, with no difference observed in smokers. No correlation between SCCa concentration and age was observed (r(2) = 0.0003). At a blocking reagent concentration of 5 mg/L, HAMA interference was eliminated in 3 samples known to produce falsely increased SCCa results. CONCLUSIONS: This SCCa ELISA demonstrates acceptable performance characteristics for quantifying serum SCCa and is effective in eliminating HAMA interference.
引用
收藏
页码:1496 / 1499
页数:4
相关论文
共 24 条
[1]  
*ABB LAB DIV D, 1997, IMX SYST SCC PACK IN
[2]   Prognostic value of preoperative squamous cell carcinoma antigen level in patients surgically treated for cervical carcinoma [J].
Bolger, BS ;
Dabbas, M ;
Lopes, A ;
Monaghan, JM .
GYNECOLOGIC ONCOLOGY, 1997, 65 (02) :309-313
[3]   SQUAMOUS-CELL CARCINOMA ANTIGEN AS AN ADJUNCT TUMOR-MARKER IN PRIMARY-CARCINOMA OF THE LUNG [J].
CHEAH, PL ;
LIAM, CK ;
YAP, SF ;
LOOI, LM .
JOURNAL OF CLINICAL PATHOLOGY, 1994, 47 (06) :535-537
[4]  
DUK JM, 1989, CANCER-AM CANCER SOC, V64, P1652, DOI 10.1002/1097-0142(19891015)64:8<1652::AID-CNCR2820640816>3.0.CO
[5]  
2-M
[6]  
Emoto M, 2000, CANCER, V88, P2298, DOI 10.1002/(SICI)1097-0142(20000515)88:10<2298::AID-CNCR14>3.0.CO
[7]  
2-S
[8]   Serum tumor markers in the management of ovarian, endometrial and cervical cancer [J].
Gadducci, A ;
Cosio, S ;
Carpi, A ;
Nicolini, A ;
Genazzani, AR .
BIOMEDICINE & PHARMACOTHERAPY, 2004, 58 (01) :24-38
[9]  
KATO H, 1984, GANN, V75, P433
[10]  
KATO H, 1977, CANCER-AM CANCER SOC, V40, P1621, DOI 10.1002/1097-0142(197710)40:4<1621::AID-CNCR2820400435>3.0.CO