Continuous quality improvement using intelligent infusion pump data analysis

被引:21
作者
Breland, Burnis D. [1 ]
机构
[1] Med Ctr Inc, Columbus Reg Healthcare Syst, Columbus, GA 31901 USA
关键词
Compliance; Computers; Devices; Drug administration; Errors; medication; Hospitals; Quality assurance; Toxicity; TECHNOLOGY; ERRORS; SAFETY;
D O I
10.2146/ajhp090588
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose. The use of continuous quality-improvement (CQI) processes in the implementation of intelligent infusion pumps in a community teaching hospital is described. Summary. After the decision was made to implement intelligent i.v. infusion pumps in a 413-bed, community teaching hospital, drug libraries for use in the safety software had to be created. Before drug libraries could be created, it was necessary to determine the epidemiology of medication use in various clinical care areas. Standardization of medication administration was performed through the CQI process, using practical knowledge of clinicians at the bedside and evidence-based drug safety parameters in the scientific literature Post-implementation, CQI allowed refinement of clinically important safety limits while minimizing inappropriate, meaningless soft limit alerts on a few select agents. Assigning individual clinical care areas (CCAs) to individual patient care units facilitated customization of drug libraries and identification of specific CCA compliance concerns. Between June 2007 and June 2008, there were seven library updates. These involved drug additions and deletions, customization of individual CCAs, and alterations of limits. Overall compliance with safety software use rose over time, from 33% in November 2006 to over 98% in December 2009. Many potentially clinically significant dosing errors were intercepted by the safety software, prompting edits by end users. Only 4-6% of soft limit alerts resulted in edits. Conclusion. Compliance rates for use of infusion pump safety software varied among CCAs over time. Education, auditing, and refinement of drug libraries led to improved compliance in most CCAs
引用
收藏
页码:1446 / 1455
页数:10
相关论文
共 10 条
[1]   Use of failure mode and effects analysis in improving the safety of iv drug administration [J].
Adachi, W ;
Lodolce, AE .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2005, 62 (09) :917-920
[2]  
Baranowski L, 1995, J Intraven Nurs, V18, P162
[3]  
BOOTMAN IL, 2006, PREVENTING MED ERROR
[4]  
Cassano A., 2006, HOSP PHARM, V41, P151
[5]  
COLOMA LH, 2008, SEC WIR 4 INF DEV IS
[6]   Impact of smart infusion technology on administration of anticoagulants (unfractionated heparin, argatroban, lepirudin, and bivalirudin) [J].
Fanikos, John ;
Fiumara, Karen ;
Baroletti, Steve ;
Luppi, Carol ;
Saniuk, Catherine ;
Mehta, Amar ;
Silverman, Jon ;
Goldhaber, Samuel Z. .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (07) :1002-1005
[7]  
*I SAF MED PRACT, 2009, P ISMP SUMM US SMART, P1
[8]   Standard drug concentrations and smart-pump technology reduce continuous-medication-infusion errors in pediatric patients [J].
Larsen, GY ;
Parker, HB ;
Cash, J ;
O'Connell, M ;
Grant, MJC .
PEDIATRICS, 2005, 116 (01) :E21-E25
[9]  
Rosenthal Kelli, 2004, Nurs Manage, V35, P49, DOI 10.1097/00006247-200405000-00015
[10]   Ethnographic study of incidence and severity of intravenous drug errors [J].
Taxis, K ;
Barber, N .