Numerical thermal optimization of the configuration of multi-holed clay bricks used for constructing building walls by the finite volume method

被引:58
作者
Li, L. P. [1 ]
Wu, Z. G. [1 ]
Li, Z. Y. [1 ]
He, Y. L. [1 ]
Tao, W. Q. [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-holed clay bricks; equivalent thermal conductivity; numerical simulation; conduction; natural convection; surface radiation;
D O I
10.1016/j.ijheatmasstransfer.2007.06.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
A comprehensive numerical study of the equivalent thermal conductivity of a multi-holed clay brick with the size of 240 x 115 x 90 (in mm) has been conducted, and 50 kinds of combination of holes and arrangements are examined. The indoor-outdoor temperature difference varies from 50 degrees C to 20 degrees C. The effects of following factors are studied in details: the hole surface radiation, the width-wise and length-wise hole numbers, and the indoor-outdoor temperature difference. The major findings are as follows: (1) the radiation between hole surfaces has some effect on the equivalent thermal conductivity, thus it should be taken into account; (2) the hole number and arrangement affect the thermal conductivity in a rather complicated manner. Analysis shows that depending on the relative importance of natural convection, surface radiation and heat conduction through the clay solid, the thermal conductivity may decrease with the hole number or increase with the hole number and (3) among the 50 kinds of combination, the optimum configuration is found which has five length-wise holes, four width-wise holes and all the holes are from bottom to top in the depth direction of a brick. Its equivalent thermal conductivity is 0.419 W/(m K), which is only 53.1% of solid clay of which it is made, showing great energy-saving possibility if it is adopted in the construction of building wall. Detailed discussion of the simulated results is conducted and flow field and temperature distributions are also provided for some typical configurations. (c) 2008 Published by Elsevier Ltd.
引用
收藏
页码:3669 / 3682
页数:14
相关论文
共 18 条
[1]   Natural convection from heated room surfaces [J].
Awbi, HB ;
Hatton, A .
ENERGY AND BUILDINGS, 1999, 30 (03) :233-244
[2]   NATURAL-CONVECTION FLOW IN A SQUARE CAVITY REVISITED - LAMINAR AND TURBULENT MODELS WITH WALL FUNCTIONS [J].
BARAKOS, G ;
MITSOULIS, E ;
ASSIMACOPOULOS, D .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 1994, 18 (07) :695-719
[3]   Radiation - natural convection heat transfer in an inclined rectangular enclosure [J].
Bouali, H ;
Mezrhab, A ;
Amaoui, H ;
Bouzidi, M .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2006, 45 (06) :553-566
[4]  
CARDOSO SC, 2003, TRANSFERTS CHALEUR S, P507
[5]   Analysis and optimization of the heat-insulating light concrete hollow brick walls design by the finite element method [J].
del Coz Diaz, J. J. ;
Garcia Nieto, P. J. ;
Betegon Biempica, C. ;
Prendes Gero, M. B. .
APPLIED THERMAL ENGINEERING, 2007, 27 (8-9) :1445-1456
[6]   Non-linear thermal analysis of light concrete hollow brick walls by the finite element method and experimental validation [J].
Díaz, JJD ;
Nieto, PJG ;
Rodríguez, AM ;
Martínez-Luengas, AL ;
Biempica, CB .
APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) :777-786
[7]   Surface radiation with conduction and natural convection in a two-floor enclosure [J].
Ergin, S .
ENERGY AND BUILDINGS, 2000, 32 (01) :57-70
[8]  
INCROPERA FP, 2003, INTRO HEAT TRANSFER
[9]   Two-dimensional model for the double glass naturally ventilated window [J].
Ismail, KAR ;
Henriquez, JR .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (3-4) :461-475
[10]   Heat transfer by natural convection in domestic refrigerators [J].
Laguerre, O ;
Flick, D .
JOURNAL OF FOOD ENGINEERING, 2004, 62 (01) :79-88