Meniscal tear biomechanics: Loads across meniscal tears in human cadaveric knees

被引:31
作者
Richards, David P. [2 ]
Barber, F. Alan [1 ]
Herbert, Morley A. [3 ]
机构
[1] Plano Orthoped & Sports Med Ctr, Plano, TX 75093 USA
[2] Scott White Clin, Temple, TX USA
[3] Med City Dallas Hosp, Adv Surg Inst, Dallas, TX USA
关键词
D O I
10.3928/01477447-20080401-32
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study examined the forces during motion across human meniscal tears. Longitudinal cuts were created in 6 human cadaveric knees at the red-white junction of the medial and lateral menisci into which a pressure transducer was placed. Pressure data were gathered with the knees at neutral, internal rotation, and external rotation and matched to knee flexion. The meniscal cuts were compressed throughout the range of motion. No distraction pressures were observed. Therefore, meniscal tear displacement does not occur with knee motion and a meniscal repair device load-to-failure strength may be less important than the device's ability to accurately reduce a meniscal tear and avoid shear stress.
引用
收藏
页码:347 / 350
页数:4
相关论文
共 40 条
[1]   Failure strength of a new meniscus arrow repair technique: Biomechanical comparison with horizontal suture [J].
AlbrechtOlsen, P ;
Lind, T ;
Kristensen, G ;
Falkenberg, B .
ARTHROSCOPY, 1997, 13 (02) :183-187
[2]   Rapid progression of chondral disease in the lateral compartment of the knee following meniscectomy [J].
Alford, JW ;
Lewis, P ;
Kang, RW ;
Cole, BJ .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (12) :1505-1509
[3]   Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time - An in vitro experimental study [J].
Arnoczky, SP ;
Lavagnino, M .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (02) :118-123
[4]  
Arnoczky SP, 1988, INJURY REPAIR MUSCUL, P487
[5]   Strength of different meniscus suturing techniques [J].
Aşik M. ;
Şener N. ;
Akpinar S. ;
Durmaz H. ;
Göksan A. .
Knee Surgery, Sports Traumatology, Arthroscopy, 1997, 5 (2) :80-83
[6]   MENISCAL TEARS - THE EFFECT OF MENISCECTOMY AND OF REPAIR ON INTRAARTICULAR CONTACT AREAS AND STRESS IN THE HUMAN KNEE - A PRELIMINARY-REPORT [J].
BARATZ, ME ;
FU, FH ;
MENGATO, R .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1986, 14 (04) :270-275
[7]   Arthroscopic meniscal repair using the BioStinger [J].
Barber, FA ;
Johnson, DH ;
Halbrecht, JL .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (06) :744-750
[8]   Load to failure testing of new meniscal repair devices [J].
Barber, FA ;
Herbert, MA ;
Richards, DP .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (01) :45-50
[9]   Meniscal repair devices [J].
Barber, FA ;
Herbert, MA .
ARTHROSCOPY, 2000, 16 (06) :613-618
[10]   ACCELERATED REHABILITATION FOR MENISCUS REPAIRS [J].
BARBER, FA .
ARTHROSCOPY, 1994, 10 (02) :206-210