Influence of the Parameters of Discharge Circuit in a Gas-Discharge Defect Transducer and of the Speed of Wire Motion on the Error of Measuring the Extent of Defects in Wire Insulation

被引:0
作者
Smirnov, G. V. [1 ]
Mirzoev, A. Kh. [1 ]
机构
[1] Tomsk State Univ Control Syst & Radioelect, Tomsk 634045, Russia
关键词
testing; defect; extent; primary defect transducer; error; speed sensor; voltage; time constant;
D O I
10.1134/S1061830920030092
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
It is shown that the systematic error in determining the extent of a defect is mainly affected by two factors: the testing voltage U across the gas-discharge defect sensor and the time constant tau = RC documentclass[12pt]{minimal} of sensor's discharge circuit. It has ben established that the wire speed does not have significant effect on this error. The practical application of the established regularities to increasing the accuracy of monitoring the extent of defects in the insulation of a wire using defect meters with a gas discharge sensor is shown.