Evaluation of the performance of orthodontic devices using FBG sensors

被引:4
|
作者
Carvalho, L. [1 ]
Roriz, P. [1 ]
Frazao, O. [1 ,2 ]
Marques, M. B. [1 ,2 ]
机构
[1] INESCTEC, P-4200465 Oporto, Portugal
[2] Univ Porto, Fac Sci, P-4150179 Oporto, Portugal
关键词
RAPID MAXILLARY EXPANSION;
D O I
10.1088/1742-6596/605/1/012017
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cross-bite, as a malocclusion effect, is defined as a transversal changing of the upper dental arch, in relation to the lower arch, and may be classified as skeletal, dental or functional. As a consequence, the expansion of maxilla is an effective clinical treatment used to correct transversal maxillary discrepancy. The maxillary expansion is an ancient method used in orthodontics, for the correction of the maxillary athresia with posterior crossbite, through the opening of the midpalatal suture (disjunction), using orthodontic-orthopaedic devices. Same controversial discussion arises among the clinicians, about the effects of each orthodontic devices as also about the technique to be employed. The objective of this study was to compare the strain field induced by two different orthodontic devices, named disjunctor with and without a connecting bar, in an acrylic model jaw, using fiber Bragg grating sensors to measure the strain patterns. The orthodontic device disjunctor with the bar, in general, transmits higher forces and strain to teeth and maxillae, than with the disjunctor without bar. It was verified that the strain patterns were not symmetric between the left and the right sides as also between the posterior and anterior regions of the maxillae. For the two devices is also found that in addition a displacement in the horizontal plane, particularly in posterior teeth, also occurs a rotation corresponding to a vestibularization of the posterior teeth and their alveolar processes.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Evaluation of the performance of orthodontic devices using FBG sensors
    INESCTEC, Campus da FEUP, Rua Dr Roberto Frias, Porto
    4200-465, Portugal
    不详
    4150-179, Portugal
    J. Phys. Conf. Ser., 1
  • [2] Performance Evaluation of FBG Sensors under Fatigue and Weathering
    Rahmatian, Arash
    Bagchi, Ashutosh
    Nokken, Michelle
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 1022 - 1029
  • [3] Strain evaluation of strengthened concrete structures using FBG sensors
    Lau, KT
    Zhou, LM
    Ye, L
    NONDESTRUCTIVE CHARACTERIZATION OF MATERIALS IX, 1999, 497 : 303 - +
  • [4] Design and Performance Evaluation of FBG-based Temperature Sensors Network
    Spolitis, Sandis
    Lyashuk, Ilya
    Bobrovs, Vjaceslavs
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL), 2017, : 2673 - 2678
  • [5] Torsion measurement by using FBG sensors
    Tian, XG
    Tao, XM
    INTERNATIONAL CONFERENCE ON SENSORS AND CONTROL TECHNIQUES (ICSC 2000), 2000, 4077 : 154 - 164
  • [7] Orthodontic mechanics using mini implant measured by FBG
    Trannin, Pamela G.
    Milczewski, Maura S.
    de Oliveira, Walm ir
    Guariza Filho, Odilon
    Lopes, Stephani C. P. S.
    Kalinowski, Hypolito J.
    FIFTH ASIA-PACIFIC OPTICAL SENSORS CONFERENCE, 2015, 9655
  • [8] Non-destructive evaluation of composite pressure vessel by using FBG sensors
    Hao Jun-cai
    Leng An-song
    Wei Zhang
    CHINESE JOURNAL OF AERONAUTICS, 2007, 20 (02) : 120 - 123
  • [9] Improving the performance of FBG sensors in a WDM network using a simulated annealing technique
    Shi, CZ
    Zeng, N
    Chan, CC
    Liao, YB
    Jin, W
    Zhang, L
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2004, 16 (01) : 227 - 229
  • [10] Experiments of Ultrasonic Sensing Using FBG Sensors
    Shi, W. W.
    Hu, T. T.
    Tan, Y. G.
    MECHATRONICS AND INFORMATION TECHNOLOGY, PTS 1 AND 2, 2012, 2-3 : 148 - 152