Purpose This prospective study evaluated the functional outcome and union rates of open distal femoral fractures managed with anatomic lateral locking plates. Methods Thirty-four patients with open distal femur fractures with mean age of 40.8 years (range 20-65 years) were included in the study. Patients with Gustilo-Anderson grade IIIC fractures and those managed with non-locking modalities were excluded. In total, 70.6% (n = 24) of the fractures were Type IIIA and 55.9% (n = 19) were AO/OTA Type C3 fractures. In 23.5% (n = 8) patients, knee spanning external fixator was applied initially before definitive fixation. Patients were followed up for a mean period of 11.6 months (range 8-22.5 months). Functional outcome was evaluated using Sanders Score. Results In the primary plating group, 69.2% (n = 18) fractures united at an average of 27 weeks (range 21-40 weeks), while eight patients had non-union and required bone grafting. All eight patients with external fixator underwent lateral locked plating with bone grafting and united at an average time of 39.6 weeks (range 31-50 weeks). There were two cases each of infection and screw failure. The final mean Sanders Score was 30.1 (range19-40) with 73.5% (n = 25) patients having good to excellent functional outcomes. Conclusions Lateral locking plates offer excellent stability to allow fracture union in open distal femoral fractures. A proactive approach to identify and manage potential healing difficulties is advisable to promote bone healing.
引用
收藏
页码:725 / 733
页数:9
相关论文
共 50 条
  • [21] A comparison of distal femoral locking plates for distal femur fractures: Long working length versus short working length
    Shah, Faaiz Ali
    Ali, Mian Amjad
    Hassan, Waqar
    Bukhari, Syed Imran
    Bukhari, Syed Imran
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2022, 72 (11) : 2154 - 2159
  • [22] Analysis of risk factors for revision in distal femoral fractures treated with lateral locking plate: a retrospective study in Chinese patients
    Hou, Guojin
    Zhou, Fang
    Tian, Yun
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    Lv, Yang
    Yang, Zhongwei
    Zhang, Yawen
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [23] Clinical Outcomes of Distal Femoral Fractures in the Geriatric Population Using Locking Plates With a Minimally Invasive Approach
    Doshi, Hitendra K.
    Wenxian, Png
    Burgula, Maitra Vaarun
    Murphy, Diarmuid Paul
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2013, 4 (01) : 16 - 20
  • [24] SURGICAL OUTCOME OF DISTAL FEMORAL FRACTURES TREATED WITH LOCKING COMPRESSION PLATE- A PROSPECTIVE STUDY
    Isaac, Jenson
    Krishnan, Vijay
    Sowmiya, K. R.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (25): : 1969 - 1973
  • [25] Management of distal femoral periprosthetic fractures by distal femoral locking plate: A retrospective study.
    Thukral, Rajiv
    Marya, S. K. S.
    Singh, Chandeep
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (02) : 199 - 207
  • [26] A comparison of proximal femoral locking compression plates with dynamic hip screws in extracapsular femoral fractures
    Zhong, B.
    Zhang, Y.
    Zhang, C.
    Luo, C. -F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (06) : 663 - 668
  • [27] Given the encouraging results of biomechanical studies on femoral neck fractures, are locking plates more safe?
    Hancioglu, S.
    Gem, K.
    Tosyali, H. K.
    Okcu, G.
    ACTA ORTHOPAEDICA BELGICA, 2024, 90 (02): : 279 - 285
  • [28] Functional Outcomes in Volar-Displaced Distal Radius Fractures Patients with Marginal Rim Fragment Treated by Volar Distal Locking Plates
    Naito, Kiyohito
    Sugiyama, Yoichi
    Kinoshita, Mayuko
    Obata, Hiroyuki
    Goto, Kenji
    Nagura, Nana
    Iwase, Yoshiyuki
    Obayashi, Osamu
    Kaneko, Kazuo
    JOURNAL OF HAND AND MICROSURGERY, 2019, 11 (02) : 100 - 105
  • [29] Outcome of Distal Femoral Fracture Treated with Locking Plate
    Zardad, Muhammad Shoaib
    Awan, Abdus S.
    Younas, Muhammad
    Shah, Shahkeel A.
    Akhtar, S. Sohail
    Shah, Matiullah
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (06): : 2142 - 2144
  • [30] Application of distal femoral 90° locking plate in children with supracondylar femoral fractures
    Zhang, Y. -J.
    Wang, Y. -J.
    Wang, S. -H.
    Song, X. -L.
    Zhao, N.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (17) : 7956 - 7967