Transluminal aortic valve placement - A feasibility study with a newly designed collapsible aortic valve

被引:20
作者
Moazami, N
Bessler, M
Argenziano, M
Choudhri, AF
Cabreriza, SE
Allendorf, JDF
Rose, EA
Oz, MC
机构
[1] Department of Surgery, Columbia-Presbyterian Medical Center, New York, NY
[2] Columbia-Presbyterian Medical Center, New York, NY 10032
关键词
D O I
10.1097/00002480-199609000-00016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Percutaneous stents are used in vascular applications in conjunction with angioplasty and in combination with graft material for repair of abdominal aneurysms. The authors have designed a collapsible bioprosthetic aortic valve for placement by a transluminal catheter technique. This trileaflet stent valve is composed of stainless steel and bovine pericardium. Stent valves, 23 and 29 mm, were tested in a pulse duplicator system with rigid rings from 21 to 31 mm in 2 mm increments. At a mean flow of 3.1 L/min (+/-0.7), normal systemic aortic pressure was generated with a transvalvular gradient of 14.9 +/- 7 mmHg (mean +/- SD). Regurgitation fraction ranged from 10 to 18% (mean 13.8 +/- 3%) in the best ring size. Valves with the best hemodynamic profile were used for implantation in three 70 kg pigs in an open chest model. The valve was collapsed in a 24 Fr catheter designed to allow slow, controlled release. After resection of the native leaflets, the new valve was placed in the subcoronary position. No additional sutures were used for securing the valve. Two animals were successfully weaned from cardiopulmonary bypass and maintained systemic pressures of 100/45 (+/-10) and 116/70 (+/-15) mmHg, respectively. Intraoperative color echocardiography revealed minimal regurgitation, central flow, full apposition of all leaflets, and no interference with coronary blood flow. Both animals were sacrificed after being off bypass for 2 hr. Postmortem examination revealed the valves to be securely anchored. The third animal was weaned from cardiopulmonary bypass but developed refractory ventricular fibrillation because of valve dislodgment due to structural failure. Although long term survival data are needed, development of a hemodynamically acceptable prosthetic aortic valve for transluminal placement is feasible.
引用
收藏
页码:M381 / M385
页数:5
相关论文
共 12 条
  • [1] TRANSLUMINAL IMPLANTATION OF ARTIFICIAL-HEART VALVES - DESCRIPTION OF A NEW EXPANDABLE AORTIC-VALVE AND INITIAL RESULTS WITH IMPLANTATION BY CATHETER TECHNIQUE IN CLOSED CHEST PIGS
    ANDERSEN, HR
    KNUDSEN, LL
    HASENKAM, JM
    [J]. EUROPEAN HEART JOURNAL, 1992, 13 (05) : 704 - 708
  • [2] AROM KV, 1991, AORTIC VALVE, P187
  • [3] BJORK VO, 1987, CARDIAC SURG STATE A, P183
  • [4] TRANSFEMORAL ENDOVASCULAR AORTIC GRAFT PLACEMENT
    CHUTER, TAM
    GREEN, RM
    OURIEL, K
    FIORE, WM
    DEWEESE, JA
    QUERAL, LA
    CRIADO
    NATH, RL
    BERKOWITZ, HD
    SUMPIO, BE
    [J]. JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) : 185 - 197
  • [5] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [6] STABILIZATION OF PERICARDIAL TISSUE BY DYE-MEDIATED PHOTOOXIDATION
    MOORE, MA
    BOHACHEVSKY, IK
    CHEUNG, DT
    BOYAN, BD
    CHEN, WM
    BICKERS, RR
    MCILROY, BK
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (05): : 611 - 618
  • [8] DEVELOPMENT AND INITIAL EXPERIMENTAL EVALUATION OF A PROSTHETIC AORTIC-VALVE FOR TRANSCATHETER PLACEMENT - WORK IN PROGRESS
    PAVCNIK, D
    WRIGHT, KC
    WALLACE, S
    [J]. RADIOLOGY, 1992, 183 (01) : 151 - 154
  • [9] Rosenberg G, 1981, ASAIO J, V4, P41
  • [10] A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    SERRUYS, PW
    DEJAEGERE, P
    KIEMENEIJ, F
    MACAYA, C
    RUTSCH, W
    HEYNDRICKX, G
    EMANUELSSON, H
    MARCO, J
    LEGRAND, V
    MATERNE, P
    BELARDI, J
    SIGWART, U
    COLOMBO, A
    GOY, JJ
    VANDENHEUVEL, P
    DELCAN, J
    MOREL, MA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 489 - 495