Graphics processing unit based dispersion encoded full-range frequency domain OCT

被引:0
作者
Wang, Ling [1 ,2 ]
Povazay, Boris [3 ]
Guggenheim, Jeremy A. [1 ]
Drexler, Wolfgang [3 ]
Hofer, Bernd [3 ]
机构
[1] Cardiff Univ, Sch Optometry & Vis Sci, Cardiff, S Glam, Wales
[2] Katholieke Univ Leuven, Fac Biosci Engn, Dept Biosyst, Leuven, Belgium
[3] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
来源
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI | 2012年 / 8213卷
基金
英国生物技术与生命科学研究理事会;
关键词
Optical coherence tomography; graphics processing unit; full range; dispersion; medical imaging; interferometers; OPTICAL COHERENCE TOMOGRAPHY; AXIAL SCANS; NM;
D O I
10.1117/12.911247
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Standard FD-OCT systems suffer from a limited useful depth range due to the inherent complex conjugate artifacts and continuous fall-off in sensitivity with distance from the zero delay. The techniques of dispersion encoded full range (DEFR) frequency-domain optical coherence tomography (FD-OCT) and its enhanced version fast DEFR use the dispersion mismatch between sample and reference arm to double the imaging depth range by iteratively suppressing complex conjugate artifacts. Previously the computational complexity of DEFR prevented its application to fields where real-time visualization or large volumetric datasets are needed. A graphics processing unit (GPU) with hundreds of processing cores provides highly parallel computation capability to FD-OCT in which processing for each A-line is identical and independent. In this paper, we adopted GPUs to accelerate DEFR, thereby significantly improving reconstruction speed by a factor of > 90 in respect to CPU based processing. A maximum display line rate of similar to 21 k-lines/s for 2048 points/A-line using 10 iterations of the fast DEFR algorithm has been successively achieved, thereby enabling the application of DEFR in fields where real time visualization is required. By comparison in the conjugate artifact suppressed cross-sectional image of a mouse eye, there is no significant qualitative difference between the corresponding CPU- and GPU-processed images.
引用
收藏
页数:6
相关论文
共 12 条
[1]  
[Anonymous], 2008, OPTICAL COHERENCE TO
[2]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[3]   Fast dispersion encoded full range optical coherence tomography for retinal imaging at 800 nm and 1060 nm [J].
Hofer, Bernd ;
Povazay, Boris ;
Unterhuber, Angelika ;
Wang, Ling ;
Hermann, Boris ;
Rey, Sara ;
Matz, Gerald ;
Drexler, Wolfgang .
OPTICS EXPRESS, 2010, 18 (05) :4898-4919
[4]   Dispersion encoded full range frequency domain optical coherence tomography [J].
Hofer, Bernd ;
Povazay, Boris ;
Hermann, Boris ;
Unterhuber, Angelika ;
Matz, Gerald ;
Drexler, Wolfgang .
OPTICS EXPRESS, 2009, 17 (01) :7-24
[5]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[6]   Fourier domain mode locking at 1050 nm for ultra-high-speed optical coherence tomography of the human retina at 236,000 axial scans per second [J].
Huber, R. ;
Adler, D. C. ;
Srinivasan, V. J. ;
Fujimoto, J. G. .
OPTICS LETTERS, 2007, 32 (14) :2049-2051
[7]   Performance and scalability of Fourier domain optical coherence tomography acceleration using graphics processing units [J].
Li, Jian ;
Bloch, Pavel ;
Xu, Jing ;
Sarunic, Marinko V. ;
Shannon, Lesley .
APPLIED OPTICS, 2011, 50 (13) :1832-1838
[8]   Ultrahigh speed Spectral/Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second [J].
Potsaid, Benjamin ;
Gorczynska, Iwona ;
Srinivasan, Vivek J. ;
Chen, Yueli ;
Jiang, James ;
Cable, Alex ;
Fujimoto, James G. .
OPTICS EXPRESS, 2008, 16 (19) :15149-15169
[9]   Real-time resampling in Fourier domain optical coherence tomography using a graphics processing unit [J].
Van der Jeught, Sam ;
Bradu, Adrian ;
Podoleanu, Adrian Gh .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (03)
[10]   Highly reproducible swept-source, dispersion-encoded full-range biometry and imaging of the mouse eye [J].
Wang, Ling ;
Hofer, Bernd ;
Chen, Yen-Po ;
Guggenheim, Jeremy A. ;
Drexler, Wolfgang ;
Povazay, Boris .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (04)