The purpose of this study was to investigate the effect of 2 different abutment types on the stress distribution in pen-implant bone and within the implant-abutment complex using 3-dimensional finite element analysis. A simple cylindrical implant (4 x 11 mm) was used in this study for efficacy calculation. One model simulated a 4.00-mm-diameter abutment connection, and the other was narrower, using a 3.2-mm-diameter abutment connection assuming a platform-switching configuration. The stress level in the cervical bone area at the implant was greatly reduced when the narrow-diameter abutment was connected compared with the regular-sized one, despite the fact that the stress level in the implant-abutment complex was increased. The results obtained in the platform-switching model can contribute to reduce the stress level at the implant-bone interface area. Results from this study showed the platform-switching procedure has the biomechanical advantage of shifting the stress concentration area away from the cervical bone-implant interface. The disadvantage of the configuration is the increasing stress in the abutment and implant-abutment junction.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 17 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[3]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[4]  
Batik A, 2007, THESIS ISTANBUL U IS
[5]   Dimension of the periimplant mucosa - Biological width revisited [J].
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1996, 23 (10) :971-973
[6]  
BRANEMARK PI, 1977, SCAND J PLAST RECONS, P7
[7]   Biological factors contributing to failures of osseointegrated oral implants - (II). Etiopathogenesis [J].
Esposito, M ;
Hirsch, JM ;
Lekholm, U ;
Thomsen, P .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (03) :721-764
[8]  
Gardner David M, 2005, N Y State Dent J, V71, P34
[9]   Application of finite element analysis in implant dentistry: A review of the literature [J].
Geng, JP ;
Tan, KBC ;
Liu, GR .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (06) :585-598
[10]   Crestal bone changes around titanium implants. A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible [J].
Hermann, JS ;
Cochran, DL ;
Nummikoski, PV ;
Buser, D .
JOURNAL OF PERIODONTOLOGY, 1997, 68 (11) :1117-1130