Experimental investigations of the response of films to heavy-ion irradiation

被引:36
作者
Spielberger, B
Scholz, M
Krämer, M
Kraft, G
机构
[1] Gesell Schwerionenforsch mbH, D-64291 Darmstadt, Germany
[2] Radiol Klin, Heidelberg, Germany
关键词
D O I
10.1088/0031-9155/46/11/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The response of films to heavy-ion irradiation was investigated systematically by recording dose-response curves for protons and carbon ions in an energy range of 8-430 MeV u(-1). In order to allow for an objective comparison of different experimental results, a practicable method was developed to decouple the value of the net optical density from the film's processing conditions and a precise definition of the film response was deduced. A qualitative explanation of the strong variation of the film response depending on particle type and energy is given, based on the particle's track structure. The data presented here form the basis for using films for dosimetry in mixed particle radiation fields and their application in the heavy-ion therapy project at GSI, Darmstadt.
引用
收藏
页码:2889 / 2897
页数:9
相关论文
共 10 条
[1]  
BATHELT B, 2000, THESIS KASSEL GERMAN
[2]   Efficiency of thermoluminescent detectors to heavy charged particles [J].
Geiss, OB ;
Kramer, M ;
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 142 (04) :592-598
[3]  
Golovkov M, 1997, INT CONGR SER, V1144, P316
[4]   Tumortherapy with ion beams [J].
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 454 (01) :1-10
[5]   CALCULATIONS OF HEAVY-ION TRACK STRUCTURE [J].
KRAMER, M ;
KRAFT, G .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1994, 33 (02) :91-109
[6]   TRACK STRUCTURE AND THE CALCULATION OF BIOLOGICAL EFFECTS OF HEAVY CHARGED-PARTICLES [J].
SCHOLZ, M ;
KRAFT, G .
PHYSICAL, CHEMICAL, BIOCHEMICAL AND BIOLOGICAL TECHNIQUES AND PROCESSES, 1996, 18 (1/2) :5-14
[7]  
SCHOLZ M, 1994, RADIAT PROT DOSIM, V52, P29
[8]  
Suchowerska N., 1997, Australasian Physical and Engineering Sciences in Medicine, V20, P20
[9]   How much does film sensitivity increase at depth for larger field sizes? [J].
Sykes, JR ;
James, HV ;
Williams, PC .
MEDICAL PHYSICS, 1999, 26 (02) :329-330
[10]   FILM DOSIMETRY OF MEGAVOLTAGE PHOTON BEAMS - A PRACTICAL METHOD OF ISODENSITY-TO-ISODOSE CURVE CONVERSION [J].
WILLIAMSON, JF ;
KHAN, FM ;
SHARMA, SC .
MEDICAL PHYSICS, 1981, 8 (01) :94-98