Partial discharge testing of motor and generator windings: An absolute or a comparison test?

被引:1
|
作者
Stone, GC [1 ]
Kantardziski, P [1 ]
机构
[1] Iris Power Engn Inc, Etobicoke, ON, Canada
关键词
D O I
10.1109/ISEIM.1998.741685
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) tests on operating motors and generators are now widely used around the world to assess the condition of the stator winding insulation. Data is presented which shows that the calibration into picoCoulumbs can yield misleading interpretations. The reasons for this are discussed. The conclusion is that with present technology, PD testing of stator windings can only be comparative.
引用
收藏
页码:63 / 66
页数:4
相关论文
共 50 条
  • [21] Design of a Pulse Generator for Testing Partial Discharge Measurement Systems
    Hejtmanek, Tomas
    Judd, Martin D.
    Drexler, Petr
    Stewart, Brian G.
    2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 690 - 693
  • [22] Contribution of Electrical–Thermal Aging to Slot Partial Discharge Properties of HV Motor Windings
    Ailiang Kang
    Muqin Tian
    Jiancheng Song
    Lingyan Lin
    Wei Li
    Zhipeng Lei
    Journal of Electrical Engineering & Technology, 2019, 14 : 1287 - 1297
  • [23] Analysis of Transition Cause of Partial Discharge Patterns in High Voltage Motor Stator Windings
    Koo, Ja-Young
    Kwak, Jun-Ho
    Kim, Hee-Dong
    Transactions of the Korean Institute of Electrical Engineers, 2024, 73 (08): : 1456 - 1460
  • [24] Contribution to Partial Discharge Analysis in Inverter-fed Motor Windings for Automotive Application
    Benmamas, Loucif
    Teste, Philippe
    Krebs, Guillaume
    Odic, Emmanuel
    Vangraefschepe, Franck
    Hamiti, Tahar
    2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 348 - 351
  • [25] Development and Validation of Estimation of Breakdown Voltage of Stator Windings of Generator From Partial Discharge Magnitude
    Nakamura, Shin
    Kanegami, Masaki
    Kuraishi, Takashi
    Miyazaki, Satoru
    ELECTRICAL ENGINEERING IN JAPAN, 2025, 218 (01)
  • [26] Development and Validatiton of Estimation of Breakdown Voltage of Stator Windings of Generator from Partial Discharge Magnitude
    Nakamura, Shin
    Kanegami, Masaki
    Kuraishi, Takashi
    Miyazaki, Satoru
    IEEJ Transactions on Fundamentals and Materials, 2024, 144 (12) : 415 - 422
  • [27] Research on testing system of partial discharge characteristics for mine motor based on high slope PWM pulse generator
    Feng C.
    Gao Z.
    Wei K.
    Chen P.
    Wang Y.
    Meitan Xuebao/Journal of the China Coal Society, 2019, 44 : 808 - 816
  • [28] RECENT PROBLEMS EXPERIENCED WITH MOTOR AND GENERATOR WINDINGS
    Stone, G. C.
    Sasic, M.
    Dunn, D.
    Culbert, I.
    INDUSTRY APPLICATIONS SOCIETY 56TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2009, : 51 - +
  • [29] MOTOR AND GENERATOR WINDINGS Recent problems experienced
    Stone, G. C.
    Sasic, M.
    Dunn, D.
    Culbert, I.
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2011, 17 (06) : 29 - 36
  • [30] Comparison of insulation capability of round wire and hairpin windings by partial discharge measurements
    Hanisch, Lucas Vincent
    Henke, Markus
    2022 12TH INTERNATIONAL ELECTRIC DRIVES PRODUCTION CONFERENCE (EDPC), 2022, : 109 - 114