Dose imaging in radiotherapy with an Ar-CF4 filled scintillating GEM

被引:17
作者
Fetal, S
van Eijk, CWE
Fraga, F
de Haas, J
Kreuger, R
van Vuure, TL
Schippers, JM [1 ]
机构
[1] Paul Scherrer Inst, WBGA C16, CH-5234 Villigen, Switzerland
[2] Univ Coimbra, Dept Phys, LIP Coimbra, P-3004516 Coimbra, Portugal
[3] Delft Univ Technol, Interfac Reactor Inst, NL-2629 JB Delft, Netherlands
关键词
dosimetry; medical imaging; gaseous detectors; GEM; gas-scintillation; Ar-CF4;
D O I
10.1016/S0168-9002(03)02133-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A gaseous scintillation detector consisting of a Ar + CF4 filled GEM and a CCD camera has been investigated for the application as a position sensitive dosimeter in proton-beam radiation therapy. The light yield has been measured as a function of the CF4 concentration, operating voltage, beam intensity and beam energy. In conditions where the gas gain decreases due to a lower electric field, an increase of the amount of light per secondary electron is observed. The mixture of Ar + 5% CF4 has the largest light output in absolute sense as well as per secondary electron. The scintillating Gas Electron Multiplier emits > 1.5 times more light than needed and the signal-quenching in the Bragg peak which occurs in solid scintillators is reduced by a factor 4. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 46
页数:5
相关论文
共 13 条
[1]   Charge amplification and transfer processes in the gas electron multiplier [J].
Bachmann, S ;
Bressan, A ;
Ropelewski, L ;
Sauli, F ;
Sharma, A ;
Mörmann, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 438 (2-3) :376-408
[2]   Dose-volume effects in the rat cervical spinal cord after proton irradiation [J].
Bijl, HP ;
van Luijk, P ;
Coppes, RP ;
Schippers, JM ;
Konings, AWT ;
van der Kogel, AJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (01) :205-211
[3]   Performance of a fluorescent screen and CCD camera as a two-dimensional dosimetry system for dynamic treatment techniques [J].
Boon, SN ;
van Luijk, P ;
Böhringer, T ;
Coray, A ;
Lomax, A ;
Pedroni, E ;
Schaffner, B ;
Schippers, JM .
MEDICAL PHYSICS, 2000, 27 (10) :2198-2208
[4]   Fast 2D phantom dosimetry for scanning proton beams [J].
Boon, SN ;
van Luijk, P ;
Schippers, JM ;
Meertens, H ;
Denis, JM ;
Vynckier, S ;
Medin, J ;
Grusell, E .
MEDICAL PHYSICS, 1998, 25 (04) :464-475
[5]   Optical readout of GEMs [J].
Fraga, FAF ;
Margato, LMS ;
Fetal, STG ;
Fraga, MMFR ;
Marques, RF ;
Policarpo, AJPL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2) :125-130
[6]   Quality control of GEM detectors using scintillation techniques [J].
Fraga, FAF ;
Fetal, STG ;
Marques, RF ;
Policarpo, AJPL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3) :417-422
[7]  
FRAGA MMFR, 2000, P NEW DEV PHOT BAUN, V504, P88
[8]   Intensity modulated proton therapy: A clinical example [J].
Lomax, AJ ;
Boehringer, T ;
Coray, A ;
Egger, E ;
Goitein, G ;
Grossmann, M ;
Juelke, P ;
Lin, S ;
Pedroni, E ;
Rohrer, B ;
Roser, W ;
Rossi, B ;
Siegenthaler, B ;
Stadelmann, O ;
Stauble, H ;
Vetter, C ;
Wisser, L .
MEDICAL PHYSICS, 2001, 28 (03) :317-324
[9]   THE SCINTILLATION OF CF4 AND ITS RELEVANCE TO DETECTION SCIENCE [J].
PANSKY, A ;
BRESKIN, A ;
BUZULUTSKOV, A ;
CHECHIK, R ;
ELKIND, V ;
VAVRA, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 354 (2-3) :262-269
[10]   THE 200-MEV PROTON THERAPY PROJECT AT THE PAUL-SCHERRER-INSTITUTE - CONCEPTUAL DESIGN AND PRACTICAL REALIZATION [J].
PEDRONI, E ;
BACHER, R ;
BLATTMANN, H ;
BOHRINGER, T ;
CORAY, A ;
LOMAX, A ;
LIN, SX ;
MUNKEL, G ;
SCHEIB, S ;
SCHNEIDER, U ;
TOUROVSKY, A .
MEDICAL PHYSICS, 1995, 22 (01) :37-53