PEDOT: Nafion coated microelectrode biosensor for in vivo monitoring of glutamate release in brain

被引:4
|
作者
Ganesana, Mallikarjunarao [1 ]
Trikantzopoulos, Elefterios [1 ]
Venton, B. Jill [1 ]
机构
[1] Univ Virginia, Dept Chem, McCormick Rd,Box 400319, Charlottesville, VA 22904 USA
来源
BIOSENSORS 2016 | 2017年 / 27卷
关键词
Microbiosensor; PEDOT: Nafion; glutamate;
D O I
10.1016/j.protcy.2017.04.096
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:229 / 229
页数:1
相关论文
共 18 条
  • [1] Development of a novel micro biosensor for in vivo monitoring of glutamate release in the brain
    Ganesana, Mallikarjunarao
    Trikantzopoulos, Elefterios
    Maniar, Yash
    Lee, Scott T.
    Venton, B. Jill
    BIOSENSORS & BIOELECTRONICS, 2019, 130 : 103 - 109
  • [2] A microelectrode biosensor for real time monitoring of L-glutamate release
    Tian, Faming
    Gourine, Alexander V.
    Huckstepp, Robert T. R.
    Dale, Nicholas
    ANALYTICA CHIMICA ACTA, 2009, 645 (1-2) : 86 - 91
  • [3] Challenges of simultaneous measurements of brain extracellular GABA and glutamate in vivo using enzyme-coated microelectrode arrays
    Burmeister, Jason J.
    Price, David A.
    Pomerleau, Francois
    Huettl, Peter
    Quintero, Jorge E.
    Gerhardt, Greg A.
    JOURNAL OF NEUROSCIENCE METHODS, 2020, 329
  • [4] In Vivo Glutamate Sensing inside the Mouse Brain with Perovskite Nickelate-Nafion Heterostructures
    Sun, Yifei
    Nguyen, Tran N. H.
    Anderson, Adam
    Cheng, Xi
    Gage, Thomas E.
    Lim, Jongcheon
    Zhang, Zhan
    Zhou, Hua
    Rodolakis, Fanny
    Zhang, Zhen
    Arslan, Ilke
    Ramanathan, Shriram
    Lee, Hyowon
    Chubykin, Alexander A.
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (22) : 24564 - 24574
  • [5] K+ depolarization evokes ATP, adenosine and glutamate release from glia in rat hippocampus: a microelectrode biosensor study
    Heinrich, A.
    Ando, R. D.
    Turi, G.
    Rozsa, B.
    Sperlagh, B.
    BRITISH JOURNAL OF PHARMACOLOGY, 2012, 167 (05) : 1003 - 1020
  • [6] A Platinized Carbon Fiber Microelectrode-Based Oxidase Biosensor for Amperometric Monitoring of Lactate in Brain Slices
    Dias, Candida
    Fernandes, Eliana
    Barbosa, Rui M.
    Ledo, Ana
    SENSORS, 2022, 22 (18)
  • [7] A two-dimensional imaging biosensor to monitor enhanced brain glutamate release stimulated by nicotine
    Qhobosheane, M
    Wu, DH
    Gu, GR
    Tan, WH
    JOURNAL OF NEUROSCIENCE METHODS, 2004, 135 (1-2) : 71 - 78
  • [8] Monitoring of the velocity of high-affinity glutamate uptake by isolated brain nerve terminals using amperometric glutamate biosensor
    Soldatkin, O.
    Nazarova, A.
    Krisanova, N.
    Borysov, A.
    Kucherenko, D.
    Kucherenko, I.
    Pozdnyakova, N.
    Soldatkin, A.
    Borisova, T.
    TALANTA, 2015, 135 : 67 - 74
  • [9] Real-time Monitoring of Exocytotic Glutamate Release from Single Neuron by Amperometry at an Enzymatic Biosensor
    Qiu, Quan-Fa
    Zhang, Fu-Li
    Tang, Yun
    Zhang, Xin-Wei
    Jiang, Hong
    Liu, Yan-Ling
    Huang, Wei-Hua
    ELECTROANALYSIS, 2018, 30 (06) : 1054 - 1059
  • [10] Propylene Glycol Stabilizes the Linear Response of Glutamate Biosensor: Potential Implications for In-Vivo Neurochemical Monitoring
    Rocchitta, Gaia
    Bacciu, Andrea
    Arrigo, Paola
    Migheli, Rossana
    Bazzu, Gianfranco
    Serra, Pier Andrea
    CHEMOSENSORS, 2018, 6 (04)