Cervical erector spinae plane block: a cadaver study

被引:45
|
作者
Elsharkawy, Hesham [1 ]
Ince, Iier [2 ]
Hamadnalla, Hassan [3 ]
Drae, Richard L. [4 ,5 ]
Tsui, Ban C. H. [6 ]
机构
[1] Cleveland Clin, Dept Anesthesiol, Cleveland, OH 44106 USA
[2] Ataturk Univ, Sch Med, Dept Anesthesiol & Reanimat, Erzurum, Turkey
[3] Cleveland Clin, Dept Outcomes Res, Inst Anesthesiol, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Dept Anat, Cleveland Clin, Lerner Coll Med, Cleveland, OH 44106 USA
[5] Case Western Reserve Univ, Dept Surg, Cleveland Clin, Lerner Coll Med, Cleveland, OH 44106 USA
[6] Stanford Univ, Dept Anesthesiol Perioperat & Pain Med, Palo Alto, CA 94304 USA
关键词
anatomy; brachial plexus; upper extremity;
D O I
10.1136/rapm-2019-101154
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background Cervical erector spinae plane (ESP) block has been described to anesthetize the brachial plexus (BP), however, the mechanism of its clinical effect remains unknown. As the prevertebral fascia encloses the phrenic nerves, BP and erector spinae muscles to form a prevertebral compartment, a local anesthetic injected in the cervical ESP could potentially spread throughout the prevertebral compartment. This study utilizes cadaveric models to evaluate the spread of ESP injections at the C6 and Cl levels to determine whether the injection can reach the BP and its surrounding structures. Methods For each of the five cadavers, an ESP injection posterior to the transverse process of C6 was performed on one side, and an ESP injection posterior to the transverse process of C7 was performed on the contralateral side. Injections were performed under ultrasound guidance and consisted of a 20 mL mixture of 18 mL water and 2 mL India ink. After cadaver dissection, craniocaudal and medial-lateral extent of the dye spread in relation to musculoskeletal anatomy as well as direct staining relevant nerves was recorded. The degree of dye staining was categorized as "deep," "faint," or "no." Results The phrenic nerve was deeply stained in 1 injection and faintly stained in 2 injections. Caudally, variable staining of C8 (100%) and T1 (50%) roots were seen. Faintly staining at C4 root was only seen in one sample (10%). There was variable staining of the anterior scalene muscles (40%) anterior to the BP and the rhomboid intercostal plane caudally (30%). Conclusions Ultrasound-guided cervical (C6 and C7) ESP injections consistently stain the roots of the BP and dorsal rami. This study supports the notion that the cervical ESP block has the potential to provide analgesia for patients undergoing shoulder and cervical spine surgeries.
引用
收藏
页码:552 / 556
页数:5
相关论文
共 50 条
  • [31] Evaluation of brachial plexus fascicles involvement on infraclavicular block: unfixed cadaver study
    Buarque de Gusmao, Luiz Carlos
    Brito Lima, Jacqueline Silva
    Oiticica Ramalho, Jeane da Rosa
    dos Santos Leite, Amanda Lira
    Ramos da Silva, Alberson Maylson
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2015, 65 (03): : 213 - 216
  • [32] A cadaver study comparing two approaches for performing maxillary nerve block in dogs
    Viscasillas, Jaime
    Seymour, Christopher J.
    Brodbelt, David C.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2013, 40 (02) : 212 - 219
  • [33] Anatomic Basis for Brachial Plexus Block at the Costoclavicular Space A Cadaver Anatomic Study
    Sala-Blanch, Xavier
    Reina, Miguel Angel
    Pangthipampai, Pawinee
    Karmakar, Manoj Kumar
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2016, 41 (03) : 387 - 391
  • [34] Fascial layers influence the spread of injectate during ultrasound-guided infraclavicular brachial plexus block: a cadaver study
    Brenner, D.
    Mahon, P.
    Iohom, G.
    Cronin, M.
    O'Flynn, C.
    Shorten, G.
    BRITISH JOURNAL OF ANAESTHESIA, 2018, 121 (04) : 876 - 882
  • [35] Clavipectoral fascia plane block spread: an anatomical study
    Labandeyra, Hipolito
    Heredia-Carques, Cristina
    Campoy, Jose Cros
    Valdes-Vilches, Luis Fernando
    Prats-Galino, Alberto
    Sala-Blanch, Xavier
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2024, 49 (05) : 368 - 372
  • [36] Cadaveric study of the ultrasound-guided inter-transversospinalis plane block in dogs for the cervical epaxial musculature region.
    Herrera-Linares, Manuel Enrique
    Fernandez-Parra, Rocio
    Zamora-Perarnau, Carla
    Fernandez-Salesa, Nuria
    Yaffy, Dylan
    Sanchis-Mora, Sandra
    RESEARCH IN VETERINARY SCIENCE, 2024, 180
  • [37] Anatomical landmarks for a proximal paravertebral thoracolumbar block in sheep: Cadaver and in-vivo study
    Velazquez-Delgado, Perla
    Gutierrez-Blanco, Eduardo
    Ortega-Pacheco, Antonio
    Guillermo-Cordero, Jose Leonardo
    Dzikiti, Brighton T.
    Valverde, Alexander
    CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2022, 86 (04): : 294 - 299
  • [38] A cadaver study of four approaches of ultrasound-guided infraclavicular brachial plexus block
    Sivapurapu, Vijayalakshmi
    Bhat, Ravindra R.
    Vani, Isai N.
    Raajesh, Joseph I.
    Aruna, S.
    Paulose, Deepak T.
    INDIAN JOURNAL OF ANAESTHESIA, 2020, 64 (07) : 624 - 630
  • [39] Ultrasound-guided adductor canal block: a cadaver study investigating the effect of a thigh tourniquet
    Nair, A.
    Dolan, J.
    Tanner, K. E.
    Kerr, C. M.
    Jones, B.
    Pollock, P. J.
    Kellett, C. F.
    BRITISH JOURNAL OF ANAESTHESIA, 2018, 121 (04) : 890 - 898
  • [40] Paravertebral block: cervical, thoracic, lumbar, and sacral
    Boezaart, Andre P.
    Lucas, Stephan D.
    Elliott, Clint E.
    CURRENT OPINION IN ANESTHESIOLOGY, 2009, 22 (05) : 637 - 643