Assessment of pulmonary vasculature volume with automated threshold-based 3D quantitative CT volumetry: In vitro and in vivo validation

被引:1
作者
Liu, Jingzhe [2 ]
Wu, Qingyu [1 ]
Xu, Yufeng [3 ]
Bai, Yan [2 ]
Liu, Zhibo [2 ]
Li, Hongyin [1 ]
Zhu, Jiemin [2 ]
机构
[1] Tsinghua Univ, Ctr Heart, Hosp 1, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Radiol, Hosp 1, Beijing 100084, Peoples R China
[3] Peking Univ, Dept Radiol, Hosp 1, Beijing 100871, Peoples R China
关键词
CT; Pulmonary arteries; Software validation; LEFT-VENTRICULAR FUNCTION; COMPUTED-TOMOGRAPHY; ARTERY PRESSURES; SEGMENTATION; HYPERTENSION; EMPHYSEMA; DIAMETER; GROWTH; SIZE;
D O I
10.1016/j.ejrad.2011.01.119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To validate the ability of threshold-based 3D CT volumetry to enable measurement of volume of visible pulmonary vessels on CT. Materials and methods: In vivo, 3D CT volumetry was validated in seven phantoms that consisted of silicone tubes embedded in a foam block. With the true volume value as reference standard, the accuracy of CT measurement at various lower thresholds of -600 HU, -500 HU, -300 HU and -200 HU were compared. The volume measurements obtained when filled with varied concentration of iodinated contrast media (1: 100, 1: 200 and 1: 500) were also compared. In vivo validation was performed in sixteen patients (9 men, 7 women; mean age, 52.1 years). Inter-scan and inter-observer agreement and reproducibility for pulmonary vasculature volume measurement were evaluated with Bland-Altman analysis. Results: In vitro, the mean value measured under lower threshold of -300 HU (relative error = 1.5%) were the closest to the true values and have no significant difference (P = 0.375). There were no significant differences among the phantom measurement values with different filled concentration (1: 100, 1: 200 and 1: 500). In vivo, the inter-scan reproducibility of volume measurements was good, with a correlation coefficient of 0.82 and ICC (intraclass correlation coefficient) of 0.86. Inter-observer agreement was excellent with a correlation coefficient of 0.91 and ICC of 0.95. Conclusions: The threshold-based 3D quantitative CT volumetry enables accurate and reproducible measurement of pulmonary vessels volume. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1040 / 1044
页数:5
相关论文
共 50 条
  • [41] Development And Validation Of A Deep Machine Learning Tool For Automated Intraventricular Hemorrhage Segmentation And Volume Measurement Using 3d Convolutional Neural Networks
    Wong, Alexander
    Baig, Saif
    Chen Zejia
    Volders, David
    Huynh, Thien
    STROKE, 2022, 53
  • [42] Bioengineered 3D nanocomposite based on gold nanoparticles and gelatin nanofibers for bone regeneration: in vitro and in vivo study
    Samadian, Hadi
    Khastar, Hossein
    Ehterami, Arian
    Salehi, Majid
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [43] 3D skeletonization feature based computer-aided detection system for pulmonary nodules in CT datasets
    Zhang, Weihang
    Wang, Xue
    Li, Xuanping
    Chen, Junfeng
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 92 : 64 - 72
  • [44] Volume perfusion CT (VPCT) for the differential diagnosis of patients with suspected cerebral vasospasm: Qualitative and quantitative analysis of 3D parameter maps
    Dolatowski, K.
    Malinova, V.
    Froelich, A. M. J.
    Schramm, R.
    Haberland, U.
    Klotz, E.
    Mielke, D.
    Knauth, M.
    Schramm, P.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1881 - 1889
  • [45] Automated 3D quantitative assessment and measurement of alpha angles from the femoral head-neck junction using MR imaging
    Xia, Ying
    Fripp, Jurgen
    Chandra, Shekhar S.
    Walker, Duncan
    Crozier, Stuart
    Engstrom, Craig
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (19) : 7601 - 7616
  • [46] 3D CT-based volumetric dose assessment of 2D plans using GEC-ESTRO guidelines for cervical cancer brachytherapy
    Gao, Mingcheng
    Albuquerque, Kevin
    Chi, Alex
    Rusu, Iris
    BRACHYTHERAPY, 2010, 9 (01) : 55 - 60
  • [47] Automated extraction of aorta and pulmonary artery in mediastinum from 3D chest X-ray CT images without contrast medium
    Kitasaka, T
    Mori, K
    Hasegawa, J
    Toriwaki, J
    Katada, K
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 1496 - 1507
  • [48] Clinical Use of Hematoma Volume Based On Automated Segmentation of Chronic Subdural Hematoma Using 3D U-Net
    Inomata, Takayuki
    Nakaya, Koji
    Matsuhiro, Mikio
    Takei, Jun
    Shiozaki, Hiroto
    Noda, Yasuto
    CLINICAL NEURORADIOLOGY, 2024, 34 (04) : 799 - 807
  • [49] Impact of Deep Learning 3D CT Super-Resolution on AI-Based Pulmonary Nodule Characterization
    Kim, Dongok
    Ahn, Chulkyun
    Kim, Jong Hyo
    TOMOGRAPHY, 2025, 11 (02)
  • [50] Estimation of pulmonary arterial volume changes in the normal and hypertensive fawn-hooded rat from 3D Micro-CT data
    Molthen, R
    Wietholt, C
    Haworth, S
    Dawson, C
    MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2002, 4683 : 266 - 275