Assessment of pulmonary vasculature volume with automated threshold-based 3D quantitative CT volumetry: In vitro and in vivo validation

被引:1
|
作者
Liu, Jingzhe [2 ]
Wu, Qingyu [1 ]
Xu, Yufeng [3 ]
Bai, Yan [2 ]
Liu, Zhibo [2 ]
Li, Hongyin [1 ]
Zhu, Jiemin [2 ]
机构
[1] Tsinghua Univ, Ctr Heart, Hosp 1, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Radiol, Hosp 1, Beijing 100084, Peoples R China
[3] Peking Univ, Dept Radiol, Hosp 1, Beijing 100871, Peoples R China
关键词
CT; Pulmonary arteries; Software validation; LEFT-VENTRICULAR FUNCTION; COMPUTED-TOMOGRAPHY; ARTERY PRESSURES; SEGMENTATION; HYPERTENSION; EMPHYSEMA; DIAMETER; GROWTH; SIZE;
D O I
10.1016/j.ejrad.2011.01.119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To validate the ability of threshold-based 3D CT volumetry to enable measurement of volume of visible pulmonary vessels on CT. Materials and methods: In vivo, 3D CT volumetry was validated in seven phantoms that consisted of silicone tubes embedded in a foam block. With the true volume value as reference standard, the accuracy of CT measurement at various lower thresholds of -600 HU, -500 HU, -300 HU and -200 HU were compared. The volume measurements obtained when filled with varied concentration of iodinated contrast media (1: 100, 1: 200 and 1: 500) were also compared. In vivo validation was performed in sixteen patients (9 men, 7 women; mean age, 52.1 years). Inter-scan and inter-observer agreement and reproducibility for pulmonary vasculature volume measurement were evaluated with Bland-Altman analysis. Results: In vitro, the mean value measured under lower threshold of -300 HU (relative error = 1.5%) were the closest to the true values and have no significant difference (P = 0.375). There were no significant differences among the phantom measurement values with different filled concentration (1: 100, 1: 200 and 1: 500). In vivo, the inter-scan reproducibility of volume measurements was good, with a correlation coefficient of 0.82 and ICC (intraclass correlation coefficient) of 0.86. Inter-observer agreement was excellent with a correlation coefficient of 0.91 and ICC of 0.95. Conclusions: The threshold-based 3D quantitative CT volumetry enables accurate and reproducible measurement of pulmonary vessels volume. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1040 / 1044
页数:5
相关论文
共 50 条
  • [21] In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images
    Nillesen, M. M.
    Lopata, R. G. P.
    de Boode, W. P.
    Gerrits, I. H.
    Huisman, H. J.
    Thijssen, J. M.
    Kapusta, L.
    de Korte, C. L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) : 1951 - 1962
  • [22] MR Evaluation of Left Ventricular Volumes and Function Threshold-Based 3D Segmentation Versus Short-Axis Planimetry
    Nassenstein, Kai
    de Greiff, Armin
    Hunold, Peter
    INVESTIGATIVE RADIOLOGY, 2009, 44 (10) : 635 - 640
  • [23] QUANTITATIVE DAMAGE ASSESSMENT OF CONCRETE STRUCTURES BASED ON 3D LASER SCANNING
    Mizoguchi, Tomohiro
    Koda, Yasuhiro
    Kobayashi, Yoshikazu
    Iwaki, Ichiro
    Hara, Yasuhiko
    Shirai, Kenji
    Lee, Hwa-Soo
    Wakabayashi, Hiroyuki
    2011 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2011, : 2129 - 2132
  • [24] Utilizing fully-automated 3D organ segmentation for hepatic steatosis assessment with CT attenuation-based parameters
    Yoo, Jeongin
    Joo, Ijin
    Jeon, Sun Kyung
    Park, Junghoan
    Yoon, Soon Ho
    EUROPEAN RADIOLOGY, 2024, 34 (09) : 6205 - 6213
  • [25] Prediction of survival by texture-based automated quantitative assessment of regional disease patterns on CT in idiopathic pulmonary fibrosis
    Lee, Sang Min
    Seo, Joon Beom
    Oh, Sang Young
    Kim, Tae Hoon
    Song, Jin Woo
    Lee, Sang Min
    Kim, Namkug
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1293 - 1300
  • [26] Prediction of survival by texture-based automated quantitative assessment of regional disease patterns on CT in idiopathic pulmonary fibrosis
    Sang Min Lee
    Joon Beom Seo
    Sang Young Oh
    Tae Hoon Kim
    Jin Woo Song
    Sang Min Lee
    Namkug Kim
    European Radiology, 2018, 28 : 1293 - 1300
  • [27] Automated 3D Mouse Lung Segmentation from CT Images for Extracting Quantitative Tumor Progression Biomarkers
    Ren, Ran
    Somayajula, Sangeetha
    Sevilla, Raquel
    Vanko, Amy
    Wiener, Matthew C.
    Dogdas, Belma
    Zhang, Weisheng
    MEDICAL IMAGING 2013: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2013, 8672
  • [28] Innovative device for in-vivo quantitative assessment of different wire materials using 3D models
    Adly, Mahmoud Sedky
    Adly, Aya Sedky
    Adly, Afnan Sedky
    Carayon, Delphine
    Estephan, Elias
    Cuisinier, Frederic
    JOURNAL OF SCIENCE-ADVANCED MATERIALS AND DEVICES, 2024, 9 (01):
  • [29] Segmentation of Pulmonary Blood Vessels Based on Fractional Differentiation in 3D Chest CT Images
    Gong, Zhao-Xuan
    Tan, Wenjun
    Song, Yi-Hua
    Geng, Huan
    Ren, Fu-Long
    Liang-Chen
    Zhu, Quan
    Wu, Wei-Bing
    Xu, Xin-Feng
    Zhang, Jian
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (07) : 1746 - 1749
  • [30] Development and validation of a fully automated tool to quantify 3D foot and ankle alignment using weight-bearing CT
    Van den Borre, Ide
    Peiffer, Matthias
    Huysentruyt, Roel
    Huyghe, Manu
    Vervelghe, Jean
    Pizurica, Aleksandra
    Audenaert, Emmanuel A.
    Burssens, Arne
    GAIT & POSTURE, 2024, 113 : 67 - 74