Assessment of pulmonary vasculature volume with automated threshold-based 3D quantitative CT volumetry: In vitro and in vivo validation

被引:1
|
作者
Liu, Jingzhe [2 ]
Wu, Qingyu [1 ]
Xu, Yufeng [3 ]
Bai, Yan [2 ]
Liu, Zhibo [2 ]
Li, Hongyin [1 ]
Zhu, Jiemin [2 ]
机构
[1] Tsinghua Univ, Ctr Heart, Hosp 1, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Radiol, Hosp 1, Beijing 100084, Peoples R China
[3] Peking Univ, Dept Radiol, Hosp 1, Beijing 100871, Peoples R China
关键词
CT; Pulmonary arteries; Software validation; LEFT-VENTRICULAR FUNCTION; COMPUTED-TOMOGRAPHY; ARTERY PRESSURES; SEGMENTATION; HYPERTENSION; EMPHYSEMA; DIAMETER; GROWTH; SIZE;
D O I
10.1016/j.ejrad.2011.01.119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To validate the ability of threshold-based 3D CT volumetry to enable measurement of volume of visible pulmonary vessels on CT. Materials and methods: In vivo, 3D CT volumetry was validated in seven phantoms that consisted of silicone tubes embedded in a foam block. With the true volume value as reference standard, the accuracy of CT measurement at various lower thresholds of -600 HU, -500 HU, -300 HU and -200 HU were compared. The volume measurements obtained when filled with varied concentration of iodinated contrast media (1: 100, 1: 200 and 1: 500) were also compared. In vivo validation was performed in sixteen patients (9 men, 7 women; mean age, 52.1 years). Inter-scan and inter-observer agreement and reproducibility for pulmonary vasculature volume measurement were evaluated with Bland-Altman analysis. Results: In vitro, the mean value measured under lower threshold of -300 HU (relative error = 1.5%) were the closest to the true values and have no significant difference (P = 0.375). There were no significant differences among the phantom measurement values with different filled concentration (1: 100, 1: 200 and 1: 500). In vivo, the inter-scan reproducibility of volume measurements was good, with a correlation coefficient of 0.82 and ICC (intraclass correlation coefficient) of 0.86. Inter-observer agreement was excellent with a correlation coefficient of 0.91 and ICC of 0.95. Conclusions: The threshold-based 3D quantitative CT volumetry enables accurate and reproducible measurement of pulmonary vessels volume. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1040 / 1044
页数:5
相关论文
共 50 条
  • [1] Combined automated 3D volumetry by pulmonary CT angiography and echocardiography for detection of pulmonary hypertension
    Melzig, Claudius
    Woerz, Stefan
    Egenlauf, Benjamin
    Partovi, Sasan
    Rohr, Karl
    Gruenig, Ekkehard
    Kauczor, Hans-Ulrich
    Heussel, Claus Peter
    Rengier, Fabian
    EUROPEAN RADIOLOGY, 2019, 29 (11) : 6059 - 6068
  • [2] Combined automated 3D volumetry by pulmonary CT angiography and echocardiography for detection of pulmonary hypertension
    Claudius Melzig
    Stefan Wörz
    Benjamin Egenlauf
    Sasan Partovi
    Karl Rohr
    Ekkehard Grünig
    Hans-Ulrich Kauczor
    Claus Peter Heussel
    Fabian Rengier
    European Radiology, 2019, 29 : 6059 - 6068
  • [3] Diagnostic accuracy of automated 3D volumetry of cardiac chambers by CT pulmonary angiography for identification of pulmonary hypertension due to left heart disease
    Melzig, Claudius
    Thuy Duong Do
    Egenlauf, Benjamin
    Partovi, Sasan
    Grunig, Ekkehard
    Kauczor, Hans-Ulrich
    Heussel, Claus Peter
    Rengier, Fabian
    EUROPEAN RADIOLOGY, 2022, 32 (08) : 5222 - 5232
  • [4] Automated 3D Volumetry of the Pulmonary Arteries based on Magnetic Resonance Angiography Has Potential for Predicting Pulmonary Hypertension
    Rengier, Fabian
    Woerz, Stefan
    Melzig, Claudius
    Ley, Sebastian
    Fink, Christian
    Benjamin, Nicola
    Partovi, Sasan
    von Tengg-Kobligk, Hendrik
    Rohr, Karl
    Kauczor, Hans-Ulrich
    Gruenig, Ekkehard
    PLOS ONE, 2016, 11 (09):
  • [5] Intracranial Aneurysm Segmentation in 3D CT Angiography: Method and Quantitative Validation
    Firouzian, Azadeh
    Manniesing, R.
    Flach, Z. H.
    Risselada, R.
    van Kooten, F.
    Sturkenboom, M. C. J. M.
    van der Lugt, A.
    Niessen, W. J.
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [6] Automated threshold-based 3D segmentation versus short-axis planimetry for assessment of global left ventricular function with dual-source MDCT
    Juergens, Kai Uwe
    Seifarth, Harald
    Range, Felix
    Wienbeck, Susanne
    Wenker, Mirja
    Heindel, Walter
    Fischbach, Roman
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : 308 - 314
  • [7] Automated volume measurements of pulmonary emphysema on 3-D chest CT images
    Hara, T
    Yamamoto, A
    Zhou, XR
    Iwano, S
    Itou, S
    Fujita, H
    Ishigaki, T
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1043 - 1048
  • [8] Automated segmentation of pulmonary vascular tree from 3D CT images
    Shikata, H
    Hoffman, EA
    Sonka, M
    MEDICAL IMAGING 2004: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2004, 5 (23): : 107 - 116
  • [9] Automated Segmentation of 3D CT Images Based on Statistical Atlas and Graph Cuts
    Shimizu, Akinobu
    Nakagomi, Keita
    Narihira, Takuya
    Kobatake, Hidefumi
    Nawano, Shigeru
    Shinozaki, Kenji
    Ishizu, Koich
    Togashi, Kaori
    MEDICAL COMPUTER VISION: RECOGNITION TECHNIQUES AND APPLICATIONS IN MEDICAL IMAGING, 2011, 6533 : 214 - +
  • [10] Representative elementary volume evaluation of coal microstructure based on CT 3D reconstruction
    Liu, Wei
    Han, Dongyang
    Wang, Gang
    Chu, Xiangyu
    FUEL, 2023, 336